七家水处理厂在饮用水制备过程中各处理步骤对病毒和指示菌的去除情况。

Elimination of viruses and indicator bacteria at each step of treatment during preparation of drinking water at seven water treatment plants.

作者信息

Payment P, Trudel M, Plante R

出版信息

Appl Environ Microbiol. 1985 Jun;49(6):1418-28. doi: 10.1128/aem.49.6.1418-1428.1985.

Abstract

Seven drinking water treatment plants were sampled twice a month for 12 months to evaluate the removal of indicator bacteria and cytopathogenic enteric viruses. Samples were obtained at each level of treatment: raw water, postchlorination, postsedimentation, postfiltration, postozonation, and finished (tap) water. Raw water quality was usually poor, with total coliform counts exceeding 105 to 106 CFU/liter and the average virus count in raw water of 3.3 most probable number of cytopathogenic units (MPNCU)/liter; several samples contained more than 100 MPNCU/liter. All plants distributed finished water that was essentially free of indicator bacteria as judged by analysis of 1 liter for total coliforms, fecal coliforms, fecal streptococci, coagulase-positive staphylococci, and Pseudomonas aeruginosa. The total plate counts at 20 and 35 degrees C were also evaluated as a measure of the total microbial population and were usually very low. Viruses were detected in 7% (11 of 155) of the finished water samples (1,000 liters) at an average density of 0.0006 MPNCU/liter the highest virus density measured being 0.2 MPNCU/liter. The average cumulative virus reduction was 95.15% after sedimentation and 99.97% after filtration and did not significantly decrease after ozonation or final chlorination. The viruses isolated from treated waters were all enteroviruses: poliovirus types 1, 2, and 3, coxsackievirus types B3, B4, and B5, echovirus type 7, and untyped picornaviruses.

摘要

对7个饮用水处理厂进行为期12个月的每月两次采样,以评估指示菌和细胞病变性肠道病毒的去除情况。在每个处理阶段采集样本:原水、氯化后、沉淀后、过滤后、臭氧化后和成品(自来水)。原水水质通常较差,总大肠菌群数超过10⁵至10⁶CFU/升,原水中病毒平均计数为3.3最可能数的细胞病变单位(MPNCU)/升;几个样本中病毒含量超过100 MPNCU/升。通过对1升水进行总大肠菌群、粪大肠菌群、粪链球菌、凝固酶阳性葡萄球菌和铜绿假单胞菌分析判断,所有工厂供应的成品水基本不含指示菌。还评估了20℃和35℃下的总平板计数作为总微生物种群的指标,通常非常低。在155个成品水样本(1000升)中有7%(11个)检测到病毒,平均密度为0.0006 MPNCU/升,测得最高病毒密度为0.2 MPNCU/升。沉淀后病毒平均累积去除率为95.15%,过滤后为99.97%,臭氧化或最终氯化后没有显著下降。从处理后水中分离出的病毒均为肠道病毒:1型、2型和3型脊髓灰质炎病毒,B3、B4和B5型柯萨奇病毒,7型埃可病毒和未分型微小核糖核酸病毒。

相似文献

2
Detection of enteric viruses in treated drinking water.处理后的饮用水中肠道病毒的检测
Appl Environ Microbiol. 1984 Jun;47(6):1290-4. doi: 10.1128/aem.47.6.1290-1294.1984.
3
Removal of enteric viruses from surface water at eight waterworks in The Netherlands.
Appl Environ Microbiol. 1984 May;47(5):927-32. doi: 10.1128/aem.47.5.927-932.1984.
4
Coliphages as indicators of enteroviruses.作为肠道病毒指示物的大肠杆菌噬菌体
Appl Environ Microbiol. 1984 Sep;48(3):668-70. doi: 10.1128/aem.48.3.668-670.1984.
9
Virological examination of drinking water: a Canadian collaborative study.
Can J Microbiol. 1984 Jan;30(1):105-12. doi: 10.1139/m84-018.

引用本文的文献

1
Chapter 7 Global Supply of Virus-Safe Drinking Water.第7章 病毒安全饮用水的全球供应
Perspect Med Virol. 2007;17:127-162. doi: 10.1016/S0168-7069(07)17007-5. Epub 2007 Sep 6.

本文引用的文献

2
Virological examination of drinking water: a Canadian collaborative study.
Can J Microbiol. 1984 Jan;30(1):105-12. doi: 10.1139/m84-018.
6
A survey of enteric viruses in domestic sewage.生活污水中肠道病毒的调查
Can J Microbiol. 1983 Jan;29(1):111-9. doi: 10.1139/m83-018.
7
Rapid identification and serotyping of poliovirus isolates by an immunoassay.
J Virol Methods. 1982 Dec;5(5-6):301-8. doi: 10.1016/0166-0934(82)90021-0.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验