The laboratory diagnosis of lung mycobacterioses including tuberculosis comprises the microscopic examination of sputum smear after appropriate staining such as Ziehl-Neelsen staining to observe acid-fast bacilli. This standard procedure is operator-dependant and its sensitivity depends on the duration of observation. We developed and evaluated an operator-independent microscopic examination of sputum smears for the automated detection and enumeration of acid-fast bacilli using a ZEISS Axio Scan.Z1 microscope. The sensitivity, specificity, positive predictive value, negative predictive values and accuracy were calculated using standard formulations by comparison with standard microscopic examination. After in-house parameterization of the automatic microscope and counting software, the limit of detection evaluated by seeding negative sputa with Mycobacterium bovis BCG or Mycobacterium tuberculosis H37Rv (10-10 bacilli/mL) was of 10 bacilli/mL of sputum with a 100% positivity rate. Then, the evaluation of 93 sputum specimens including 34 smear-positive and 59 smear-negative specimens yielded a sensitivity of 97.06% [84.67-99.93%], a specificity of 86.44% [73.01-92.78%]. Up to 100 smear slides could be stocked for reading in the microscope magazine and results are exportable into the laboratory information system. Based on these preliminary results, we are implanting this automatic protocol in the routine workflow so that only smears detected positive by automatic microscopy are confirmed by standard microscopic examination.

摘要

肺分枝杆菌病(包括结核病)的实验室诊断包括适当染色后(如齐-尼染色)对痰液涂片进行显微镜检查,以观察抗酸杆菌。这种标准程序依赖于操作人员,其灵敏度取决于观察时间。我们开发并评估了一种使用蔡司 Axio Scan.Z1 显微镜对痰液涂片进行自动检测和计数抗酸杆菌的非操作人员依赖的显微镜检查方法。通过与标准显微镜检查比较,使用标准公式计算了灵敏度、特异性、阳性预测值、阴性预测值和准确性。在对自动显微镜和计数软件进行内部参数化后,用牛分枝杆菌 BCG 或结核分枝杆菌 H37Rv(10-10 个细菌/mL)对阴性痰液进行播种评估的检测限为 10 个细菌/mL 痰液,阳性率为 100%。然后,对 93 份痰液标本进行评估,其中 34 份为涂片阳性,59 份为涂片阴性,灵敏度为 97.06%[84.67-99.93%],特异性为 86.44%[73.01-92.78%]。显微镜载物台可存储多达 100 张涂片以备阅读,结果可输出到实验室信息系统。基于这些初步结果,我们正在将这种自动方案植入常规工作流程中,以便只有自动显微镜检测为阳性的涂片才需要通过标准显微镜检查进行确认。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ad34/6063956/cf32ce949dbb/41598_2018_29660_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验