Institute for Infectious Diseases, University of Bern, Bern CH-3001, Switzerland.
Institute for Infectious Diseases, University of Bern, Bern CH-3001, Switzerland.
Clin Microbiol Infect. 2019 Jul;25(7):907.e7-907.e12. doi: 10.1016/j.cmi.2018.10.016. Epub 2018 Oct 28.
Highly pathogenic viruses such as EBOV are a threat to routine laboratory workers. Inactivation procedures with Triton X-100 0.1% and/or heat are currently recommended, but have unknown effects on the accuracy of serological testing. Furthermore, virus inactivation by Triton X-100 0.1% was shown to be ineffective in serum. This study aimed to demonstrate virus inactivation in serum by Triton X-100 1% and maintained accuracy of serological testing.
A panel of 19 serological tests was run on patient serum samples after treatment with Triton X-100 1%, 0.1%, and 0.1% + heat inactivation at 60°C for 1 h. Mean differences between measurements (bias) were calculated applying the Bland-Altman method. To determine effectiveness of virus inactivation, herpes simplex virus 1 (HSV-1) was spiked into medium containing 90% or 1% serum, and treated with Triton X-100 0.1% or 1%. Infectious titres were then determined on Vero cells.
Serological measurements showed good agreement between controls and samples treated with Triton X-100 0.1% and 1%, with an estimated bias of 0.6 ± 9.2% (n = 258) and -0.1 ± 18.6% (n = 174), respectively. Discordant qualitative results were rare. Conversely, heat inactivation alone and combined with Triton X-100 0.1% triggered a bias of 17.5 ± 66.4% (n = 200) and 37.9 ± 79.8% (n = 160), respectively. Triton X-100 1% completely inactivated HSV-1 in 1% and 90% serum while Triton X-100 0.1% failed to do so in 90% serum.
Unlike heat inactivation, Triton X-100 1% enabled accurate serological testing and completely inactivated HSV-1 in serum. This simple method could allow safe routine serological diagnostics in high-risk patients.
埃博拉病毒等高致病性病毒对常规实验室工作人员构成威胁。目前推荐使用 0.1% Triton X-100 和/或加热的灭活程序,但对血清学检测的准确性有未知影响。此外,已证明 0.1% Triton X-100 不能有效灭活病毒。本研究旨在证明 1% Triton X-100 可有效灭活血清中的病毒,并保持血清学检测的准确性。
用 Triton X-100 1%、0.1% 和 0.1%+60°C 1 小时热灭活处理患者血清样本后,对 19 项血清学检测进行检测。应用 Bland-Altman 法计算测量值之间的平均差异(偏差)。为确定病毒灭活的效果,将单纯疱疹病毒 1(HSV-1)加入含 90%或 1%血清的培养基中,并用 0.1%或 1% Triton X-100 处理。然后在 Vero 细胞上测定感染性滴度。
血清学检测结果显示,用 Triton X-100 0.1%和 1%处理的对照样本与样本之间具有良好的一致性,估计偏差分别为 0.6±9.2%(n=258)和-0.1±18.6%(n=174)。定性结果不一致的情况很少见。相反,单独热灭活和与 Triton X-100 0.1%联合处理分别导致偏差为 17.5±66.4%(n=200)和 37.9±79.8%(n=160)。Triton X-100 1%可完全灭活 1%和 90%血清中的 HSV-1,而 Triton X-100 0.1%在 90%血清中则不能完全灭活 HSV-1。
与热灭活不同,Triton X-100 1%可实现准确的血清学检测,并完全灭活血清中的 HSV-1。这种简单的方法可允许在高危患者中进行安全的常规血清学诊断。