1 Department of Pathology and Surgery, Miguel Hernández University, Alicante, Spain.
2 Institute for Health and Biomedical Research (ISABIAL-FISABIO Foundation), Alicante, Spain.
Clin Rehabil. 2019 Apr;33(4):724-736. doi: 10.1177/0269215518819046. Epub 2018 Dec 19.
: The aim of this study is to examine the psychometric properties of the Spanish version of the Oxford Cognitive Screen in a subacute stroke population.
: Fifty-seven subacute stroke outpatients and 54 healthy individuals were recruited in Alicante province, Spain.
: The Oxford Cognitive Screen.
: The Montreal Cognitive Assessment, the Barcelona test, and the Barthel Index.
: A validation study was conducted to analyze the inter-rater, intra-rater, test-retest, and internal consistency of the Spanish version of the Oxford Cognitive Screen. Concurrent validity was assessed using the Montreal Cognitive Assessment and the Barcelona test, and divergent validity using the Barthel index. Discriminant indices such as the sensitivity, specificity, predictive values, and optimal cut-offs were also estimated.
: The subtests of the Spanish version of the Oxford Cognitive Screen showed excellent estimates for the inter-reliability (intraclass correlation coefficient (ICC) = 0.790 to 1.000; r = 0.693 to 1.000), and acceptable-good for intra-reliability (ICC = 0.181 to 0.990) and test-retest reliability ( r = 0.173 to 0.971). Internal consistency was also excellent (standardized Cronbach's α = 0.907). Spearman correlations for the concurrent validity were low-strong ( r = -0.193 to 0.95) and low-moderate ( r = -0.091 to 0.443) for divergent validity. The optimal cut-offs estimated for the subtests of the Spanish version of the Oxford Cognitive Screen showed good-high specificity (66.7%-100%) and positive predictive value (67.9%-100%), and low-good sensitivity (14.8%-83.3%) and moderate-good negative predictive value (53.5%-76.6%). Discriminant power as measured by the area under the curve indicated acceptable-good values (0.397 to 0.894).
: Our findings support that the Spanish version of the Oxford Cognitive Screen is a reliable and valid tool for screening cognitive impairments in subacute stroke patients.
本研究旨在检验牛津认知筛查量表西班牙语版在亚急性脑卒中人群中的心理测量特性。
在西班牙阿利坎特省招募了 57 名亚急性脑卒中门诊患者和 54 名健康个体。
牛津认知筛查量表。
蒙特利尔认知评估量表、巴塞罗那测试和巴氏量表。
进行了一项验证研究,以分析牛津认知筛查量表西班牙语版的评分者间信度、评分者内信度、重测信度和内部一致性。使用蒙特利尔认知评估量表和巴塞罗那测试评估了同时效度,使用巴氏量表评估了离散效度。还估计了灵敏度、特异性、预测值和最佳截断值等判别指数。
牛津认知筛查量表西班牙语版的各个亚测试表现出极好的重测信度估计值(组内相关系数(ICC)=0.790 至 1.000;r=0.693 至 1.000),以及可接受的良好的内部一致性(ICC=0.181 至 0.990)和重测信度(r=0.173 至 0.971)。内部一致性也很好(标准化 Cronbach's α=0.907)。同时效度的 Spearman 相关系数为低-强(r=-0.193 至 0.95)和低-中度(r=-0.091 至 0.443),离散效度的 Spearman 相关系数为低-中度(r=-0.091 至 0.443)。为牛津认知筛查量表西班牙语版的各个亚测试估计的最佳截断值显示出良好-高度的特异性(66.7%-100%)和阳性预测值(67.9%-100%),以及低-良好的灵敏度(14.8%-83.3%)和中等-良好的阴性预测值(53.5%-76.6%)。曲线下面积表示的判别能力表明具有可接受-良好的值(0.397 至 0.894)。
我们的研究结果支持牛津认知筛查量表西班牙语版是一种可靠且有效的工具,可用于筛查亚急性脑卒中患者的认知障碍。