Suppr超能文献

非眼科医师在立体数字图像上测量视盘形态特征的可靠性。

Non-physician grader reliability in measuring morphological features of the optic nerve head in stereo digital images.

机构信息

Scheie Eye Institute, University of Pennsylvania, Philadelphia, PA, USA.

Scheie Eye Institute, University of Pennsylvania, Philadelphia, PA, USA. joan.o'

出版信息

Eye (Lond). 2019 May;33(5):838-844. doi: 10.1038/s41433-018-0332-8. Epub 2019 Jan 11.

Abstract

OBJECTIVE

To introduce a new method of grading optic nerve stereo disc photographs and evaluate reproducibility of assessments by non-physician graders in a reading center.

METHODS

Three non-physician graders, experienced in grading features of the retina but not the optic nerve head (ONH), were trained by glaucoma specialists to assess digital stereo color images of the ONH. These graders assessed a total of 2554 digital stereo disc images from glaucoma cases and controls participating in the Primary Open-Angle African American Glaucoma Genetics (POAAGG) study by outlining the optic cup and disc. Inter-grader reproducibility of area, height, and width measurements was analyzed.

RESULTS

Among all images, the intraclass correlation (95% confidence interval) was 0.90 (0.89, 0.90) for the cup area using only color cues; 0.92 (0.91, 0.92) for the cup area using contour and vascular cues; and 0.99 (0.99, 0.99) for the optic disc area. The intraclass correlation for cup-to-disc ratio (CDR) was 0.61 (0.58, 0.63), as determined by the ratio of optic cup area to optic disc area (using contour and vascular cues). The CDR difference by graders for area was ≤ 0.1 in 65% of images using color/vascular cues and ≤0.1 in 71% of images using color cues.

CONCLUSIONS

After adequate training, non-physician graders were able to measure the optic nerve CDR with high inter-grader reliability.

摘要

目的

介绍一种新的视神经立体盘片分级方法,并评估阅读中心非眼科医师分级员进行评估的可重复性。

方法

3 名非眼科医师分级员,具有评估视网膜特征但不评估视盘(ONH)的经验,通过眼科专家培训来评估原发性开角型非洲裔美国人青光眼遗传学(POAAGG)研究中青光眼病例和对照者的数字立体彩色 ONH 图像。这些分级员通过勾画视杯和视盘,总共评估了 2554 张来自青光眼病例和对照者的数字立体盘图像。分析了分级员之间面积、高度和宽度测量的重复性。

结果

在所有图像中,仅使用颜色线索时,杯面积的组内相关系数(95%置信区间)为 0.90(0.89,0.90);使用轮廓和血管线索时,杯面积的组内相关系数为 0.92(0.91,0.92);视盘面积的组内相关系数为 0.99(0.99,0.99)。使用轮廓和血管线索确定的杯盘比(CDR)的组内相关系数为 0.61(0.58,0.63)。使用颜色/血管线索时,分级员的杯面积差值为 0.1 的图像占 65%,使用颜色线索时,杯面积差值为 0.1 的图像占 71%。

结论

经过充分培训,非眼科医师分级员能够以较高的分级员间可靠性测量视神经 CDR。

相似文献

4
Automated assessment of the optic nerve head on stereo disc photographs.立体视盘照片上视神经乳头的自动评估。
Invest Ophthalmol Vis Sci. 2008 Jun;49(6):2512-7. doi: 10.1167/iovs.07-1229. Epub 2008 Mar 7.
7
Utility of digital stereo images for optic disc evaluation.数字立体图像在视盘评估中的应用。
Invest Ophthalmol Vis Sci. 2010 Nov;51(11):5667-74. doi: 10.1167/iovs.09-4999. Epub 2010 May 26.

引用本文的文献

本文引用的文献

2
Evaluation of the Optic Nerve Head in Glaucoma.青光眼视乳头评估
J Curr Glaucoma Pract. 2013 Sep-Dec;7(3):106-14. doi: 10.5005/jp-journals-10008-1146. Epub 2013 Sep 6.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验