Suppr超能文献

通过对比增强超声对眼内和眼外灌注进行定量、无创评估及其在健康犬中的临床适用性

Quantitative, noninvasive assessment of intra- and extraocular perfusion by contrast-enhanced ultrasonography and its clinical applicability in healthy dogs.

作者信息

Blohm Klaas-Ole, Hittmair Katharina M, Tichy Alexander, Nell Barbara

机构信息

Department for Companion Animals and Horses, Ophthalmology Service, University of Veterinary Medicine, Vienna, Austria.

Department for Companion Animals and Horses, Diagnostic Imaging, University of Veterinary Medicine, Vienna, Austria.

出版信息

Vet Ophthalmol. 2019 Nov;22(6):767-777. doi: 10.1111/vop.12648. Epub 2019 Feb 17.

Abstract

OBJECTIVE

To assess quantitative perfusion of intra- and extraocular regions of interest (ROIs) in conscious, healthy dogs utilizing contrast-enhanced ultrasonography (CEUS); to compare varying enhancement with the first and second bolus injection and in the right and left eye; and to determine the most appropriate examination time.

PROCEDURES

Gray scale ultrasonography and contrast harmonic imaging using sulfur hexafluoride were performed randomly assigned in both eyes in 10 university-owned beagles. Perfusion parameters including slope time, time to peak (TTP), peak intensity (PI), and area under the curve (AUC) were measured at individually drawn ROIs (retrobulbar cone = ROI 1, choroid-retina complex = ROI 2, medial = ROI 3, and lateral anterior uvea = ROI 4).

RESULTS

Time-intensity curve parameters revealed no significant differences in eyes examined by the first or second bolus injection (P > 0.05) or in the right or left eye (P > 0.05). Pooled data from all eyes were analyzed. Peak intensity of ROI 2 was significantly higher compared to all other ROIs (P < 0.001). Area under the curve at ROI 2 was significantly higher compared to all other ROIs (P < 0.05), and AUC at ROI 1 was significantly higher than at ROI 4 (P < 0.05). No significant differences in TTP were observed between different ROIs (P > 0.05). Ratios relative to different ROI sizes showed fastest enhancement in the retrobulbar cone and most intense perfusion in the anterior uveal regions. The first minute after contrast injection provided the highest diagnostic value.

CONCLUSION

Quantitative perfusion in nondiseased canine eyes revealed consistent parameters. Application of standardized CEUS protocols may be a promising diagnostic tool to differentiate ocular lesions.

摘要

目的

利用对比增强超声(CEUS)评估清醒健康犬眼内和眼外感兴趣区域(ROI)的定量灌注;比较首次和第二次团注注射以及左右眼之间的不同增强情况;并确定最合适的检查时间。

程序

对10只大学饲养的比格犬的双眼随机进行灰阶超声检查和使用六氟化硫的对比谐波成像。在单独绘制的ROI(球后圆锥 = ROI 1、脉络膜 - 视网膜复合体 = ROI 2、内侧 = ROI 3和前葡萄膜外侧 = ROI 4)处测量灌注参数,包括斜率时间、达峰时间(TTP)、峰值强度(PI)和曲线下面积(AUC)。

结果

时间 - 强度曲线参数显示,首次或第二次团注注射检查的眼睛之间(P > 0.05)或左右眼之间(P > 0.05)无显著差异。分析了所有眼睛的汇总数据。ROI 2的峰值强度显著高于所有其他ROI(P < 0.001)。ROI 2处的曲线下面积显著高于所有其他ROI(P < 0.05),ROI 1处的AUC显著高于ROI 4处(P < 0.05)。不同ROI之间未观察到达峰时间的显著差异(P > 0.05)。相对于不同ROI大小的比率显示球后圆锥增强最快,前葡萄膜区域灌注最强烈。注射造影剂后的第一分钟提供了最高的诊断价值。

结论

未患病犬眼的定量灌注显示参数一致。应用标准化的CEUS方案可能是一种有前景的诊断工具,用于鉴别眼部病变。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fa88/6899557/5876f025a604/VOP-22-767-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验