Department of Chemistry, Faculty of Science, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand.
Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, United States.
Anal Chim Acta. 2019 May 16;1056:88-95. doi: 10.1016/j.aca.2019.01.026. Epub 2019 Jan 29.
The simultaneous detection of multiple analytes from a single sample is a critical tool for the analysis of real world samples. However, this is challenging to accomplish in the field by current electroanalytical techniques, where tuning assay conditions towards a target analyte often results in poor selectivity and sensitivity for other species in the mixture. In this work, an electrochemical paper-based analytical device (ePAD) capable of performing simultaneous electrochemical experiments in different solution conditions on a single sample was developed for the first time. We refer to the system as a Janus-ePAD after the two-faced Greek god because of the ability of the device to perform electrochemistry on the same sample under differing solution conditions at the same time with a single potentiostat. In a Janus-ePAD, a sample wicks down two channels from a single inlet towards two discreet reagent zones that adjust solution conditions, such as pH, before flow termination in two electrochemical detection zones. These zones feature independent working electrodes and shared reference and counter electrodes, facilitating simultaneous detection of multiple species at each species' optimal solution condition. The device utility and applicability are demonstrated through the simultaneous detection of two biologically relevant species (norepinephrine and serotonin) and a common enzymatic assay product (p-aminophenol) at two different solution pH conditions. Janus-ePADs show great promise as an inexpensive and broadly applicable platform which can reduce the complexity and/or number of steps required in multiplexed analysis, while also operating under the optimized conditions of each species present in a mixture.
从单个样本中同时检测多种分析物是分析实际样本的重要工具。然而,目前的电化学生物分析技术在现场实现这一目标具有挑战性,因为针对目标分析物调整分析条件通常会导致混合物中其他物种的选择性和灵敏度较差。在这项工作中,首次开发了一种能够在单个样本上同时在不同溶液条件下进行电化学实验的基于纸张的电化学生物分析装置(ePAD)。我们将该系统称为 Janus-ePAD,因为该设备能够在单个电化学工作站上同时对同一样本在不同溶液条件下进行电化学分析。在 Janus-ePAD 中,样品从单个入口虹吸到两个通道中,然后流向两个独立的试剂区,在两个电化学检测区之前调整溶液条件,例如 pH 值。这些区域具有独立的工作电极和共享的参考电极和对电极,便于在每个物种的最佳溶液条件下同时检测多种物质。该设备的实用性和适用性通过同时检测两种具有生物学相关性的物质(去甲肾上腺素和血清素)和一种常见的酶分析产物(对氨基苯酚)在两种不同的溶液 pH 值条件下得到了证明。Janus-ePAD 有望成为一种廉价且广泛适用的平台,它可以减少多指标分析所需的复杂性和/或步骤数量,同时也可以在混合物中每种物质的优化条件下运行。