Abstract

The purpose of this study was to compare invasively measured aorta flow with 2D phase contrast flow and 4D flow measurements by cardiovascular magnetic resonance (CMR) imaging in a large animal model. Nine swine (mean weight 63 ± 4 kg) were included in the study. 4D flow CMR exams were performed on a 1.5T MRI scanner. Flow measurements were performed on 4D flow images at the aortic valve level, in the ascending aorta, and main pulmonary artery. Simultaneously, flow was measured using an invasive flow probe, placed around the ascending aorta. Additionally, standard 2D phase contrast flow and 2D left ventricular (LV) volumetric data were used for comparison. The correlations of cardiac output (CO) between the invasive flow probe, and CMR modalities were strong to very strong. CO measured by 4D flow CMR correlated better with the CO measured by the invasive flow probe than 2D flow CMR flow and volumetric LV data (4D flow CMR: Spearman's rho = 0.86 at the aortic valve level and 0.90 at the ascending aorta level; 2D flow CMR: 0.67 at aortic valve level; LV measurements: 0.77). In addition, there tended to be a correlation between mean pulmonary artery flow and aorta flow with 4D flow (Spearman's rho = 0.65, P = 0.07), which was absent in measurements obtained with 2D flow CMR (Spearman's rho = 0.40, P = 0.33). This study shows that aorta flow can be accurately measured by 4D flow CMR compared to simultaneously measured invasive flow. This helps to further validate the quantitative reliability of this technique.

摘要

本研究的目的是在大型动物模型中,比较通过心血管磁共振(CMR)成像进行的有创测量的主动脉血流与二维相位对比血流及四维血流测量结果。九只猪(平均体重63±4千克)被纳入本研究。四维血流CMR检查在1.5T MRI扫描仪上进行。在主动脉瓣水平、升主动脉和主肺动脉的四维血流图像上进行血流测量。同时,使用置于升主动脉周围的有创血流探头测量血流。此外,还使用标准二维相位对比血流和二维左心室(LV)容积数据进行比较。有创血流探头与CMR模式之间的心输出量(CO)相关性很强至非常强。与二维血流CMR血流和LV容积数据相比,四维血流CMR测量的CO与有创血流探头测量的CO相关性更好(四维血流CMR:主动脉瓣水平Spearman相关系数ρ=0.86,升主动脉水平为0.90;二维血流CMR:主动脉瓣水平为0.67;LV测量值:0.77)。此外,四维血流测量的平均肺动脉血流与主动脉血流之间存在一定相关性(Spearman相关系数ρ=0.65,P=0.07),而二维血流CMR测量结果中不存在这种相关性(Spearman相关系数ρ=0.40,P=0.33)。本研究表明,与同时测量的有创血流相比,四维血流CMR能够准确测量主动脉血流。这有助于进一步验证该技术的定量可靠性。