Suppr超能文献

健康眼睛中Icare Pro眼压计与Icare One眼压计测量结果的比较。

Comparison of Icare Pro Tonometry and Icare One Tonometry Measurements in Healthy Eyes.

作者信息

Mayalı Hüseyin, Sarıgül Çağlar, Kurt Emin, Kayıkçıoğlu Özcan Rasim, İlker Süleyman Sami

机构信息

Manisa Celal Bayar University Faculty of Medicine, Department of Ophthalmology, Manisa, Turkey

出版信息

Turk J Ophthalmol. 2019 Jun 27;49(3):130-133. doi: 10.4274/tjo.galenos.2018.06787.

Abstract

OBJECTIVES

To compare intraocular pressure (IOP) measurements obtained with the Icare Pro tonometer used in clinical practice and the Icare One self-tonometer.

MATERIALS AND METHODS

Fifty-two eyes of 52 healthy, right-handed individuals with no prior intraocular surgery or ocular trauma, structural ocular pathology, or systemic disease were evaluated. IOP was first measured using the Icare Pro tonometer. The participants were then told how to use the Icare One tonometer and asked to measure their own IOP. The results were analyzed statistically using SPSS v.24.

RESULTS

Of the 52 healthy participants, 16 (30.7%) were male and 36 (69.3%) were female. Their mean age was 31.6±6.3 (23-47) years. Mean IOP measured with the Icare Pro was 17.10±6.2 (11.5-25.2) mmHg, and the mean self-measured IOP with Icare One was 14.01±3.4 (7-24) mmHg. When the two methods were compared using Levene’s t-test, there was a significant mean difference of -3.08±0.6 (95% confidence interval: -4.39 -1.78; p<0.001).

CONCLUSION

In this study, there was a significant difference between the IOP measurements we made using the Icare Pro and the participants’ self-measured IOP using the Icare One, with the latter being relatively lower. This may be related to the fact that the participants were unfamiliar with using the Icare One. Although the Icare One is a promising tool for glaucoma patients to self-monitor their IOP, further studies are needed.

摘要

目的

比较临床实践中使用Icare Pro眼压计和Icare One自动眼压计测量的眼压(IOP)。

材料与方法

对52名健康右利手个体的52只眼睛进行评估,这些个体既往无眼内手术或眼外伤史、眼部结构病变或全身性疾病。首先使用Icare Pro眼压计测量眼压。然后告知参与者如何使用Icare One眼压计,并要求他们自行测量眼压。使用SPSS v.24对结果进行统计学分析。

结果

52名健康参与者中,16名(30.7%)为男性,36名(69.3%)为女性。他们的平均年龄为31.6±6.3(23 - 47)岁。使用Icare Pro测量的平均眼压为17.10±6.2(11.5 - 25.2)mmHg,使用Icare One自行测量的平均眼压为14.01±3.4(7 - 24)mmHg。当使用Levene's t检验比较这两种方法时,平均差异显著为 - 3.08±0.6(95%置信区间: - 4.39 - 1.78;p<0.001)。

结论

在本研究中,我们使用Icare Pro测量的眼压与参与者使用Icare One自行测量的眼压之间存在显著差异,后者相对较低。这可能与参与者不熟悉使用Icare One有关。尽管Icare One是青光眼患者自我监测眼压的一个有前景的工具,但仍需要进一步研究。

相似文献

10

本文引用的文献

6
A new rebound tonometer for home monitoring of intraocular pressure.一种用于家庭眼压监测的新型回弹眼压计。
Graefes Arch Clin Exp Ophthalmol. 2011 Nov;249(11):1713-9. doi: 10.1007/s00417-011-1785-7. Epub 2011 Aug 14.
9
Changes in intraocular pressure and ocular pulse amplitude with accommodation.调节时眼压和眼脉冲幅度的变化。
Br J Ophthalmol. 2010 Mar;94(3):332-5. doi: 10.1136/bjo.2009.166355. Epub 2009 Oct 12.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验