Urologic Oncology Research Group, Cancer Research Program, Research Institute (RI) of McGill University Health Center (MUHC), Glen Campus, E M2.2210, 1001 Blvd Décarie, Montréal, Qc, H4A 3J1, Canada.
Department of Surgery (Urology Division), MUHC and McGill University, Montreal, Canada.
BMC Urol. 2019 Jul 24;19(1):68. doi: 10.1186/s12894-019-0492-2.
To define a new coefficient to be used in the formula (Volume = L x H x W x Coefficient) that better estimates prostate volume using dimensions of fresh prostates from patients who had transrectal ultrasound (TRUS) imaging prior to prostatectomy.
The prostate was obtained from 153 patients, weighed and measured to obtain length (L), height (H), and width (W). The density was determined by water displacement to calculate volume. TRUS data were retrieved from patient charts. Linear regression analyses were performed to compare various prostate volume formulas, including the commonly used ellipsoid formula and newly introduced bullet-shaped formula.
By relating measured prostate volumes from fresh prostates to TRUS-estimated prostate volumes, 0.66 was the best fitting coefficient in the (L x H x W x Coefficient) equation. This newfound coefficient combined with outlier removal yielded a linear equation with an R of 0.64, compared to 0.55 and 0.60, for the ellipsoid and bullet, respectively. By comparing each of the measured vs. estimated dimensions, we observed that the mean prostate height and length were overestimated by 11.1 and 10.8% using ultrasound (p < 0.05), respectively, while the mean width was similar (p > 0.05). Overall, the ellipsoid formula underestimates prostate volumes by 18%, compared to an overestimation of 4.6 and 5.7% for the bullet formula and the formula using our coefficient, respectively.
This study defines, for the first time, a coefficient based on freshly resected prostates as a reference to estimate volumes by imaging. Our findings support a bullet rather than an ellipsoid prostate shape. Moreover, substituting the coefficient commonly used in the ellipsoid formula by our calculated coefficient in the equation estimating prostate volume by TRUS, provides a more accurate value of the true prostate volume.
定义一个新系数,用于公式(体积=长×高×宽×系数),以更好地估计接受经直肠超声(TRUS)成像检查的前列腺切除术患者的前列腺体积。
从 153 名患者中获取前列腺,称重并测量以获得长度(L)、高度(H)和宽度(W)。通过排水法确定密度以计算体积。从患者图表中检索 TRUS 数据。进行线性回归分析以比较各种前列腺体积公式,包括常用的椭圆公式和新引入的子弹形公式。
通过将新鲜前列腺的测量体积与 TRUS 估计的前列腺体积相关联,(L x H x W x Coefficient)方程中 0.66 是最佳拟合系数。与椭圆和子弹公式分别为 0.55 和 0.60 相比,去除异常值后,新发现的系数产生了线性方程,R 值为 0.64。通过比较每个测量值与估计值的尺寸,我们观察到超声检查高估了前列腺的平均高度和长度,分别为 11.1%和 10.8%(p<0.05),而平均宽度相似(p>0.05)。总的来说,与子弹公式和我们的系数公式相比,椭圆公式低估了前列腺体积 18%,而高估了 4.6%和 5.7%。
本研究首次定义了一个基于新鲜切除的前列腺的系数,作为通过成像估计体积的参考。我们的发现支持子弹形而不是椭圆形的前列腺形状。此外,用我们计算的系数替代椭圆公式中常用的系数,在通过 TRUS 估计前列腺体积的方程中,可以提供更准确的真实前列腺体积值。