Department of Vitreo-Retina, Retina Foundation, Ahmedabad, Gujrat, India.
Retina. 2020 Aug;40(8):1574-1578. doi: 10.1097/IAE.0000000000002629.
To evaluate the functional changes on the macula, before and after silicone oil removal (SOR) using microperimetry (MP3) in patients originally operated for macula-off rhegmatogenous retinal detachments.
Prospective interventional study, N = 20. All cases underwent complete ophthalmic examination, including determination of Snellen best-corrected visual acuity, indirect ophthalmoscopy, and MP3 for measuring retinal sensitivity. Primary outcome measure was to describe the alterations in the retinal sensitivity on the macula after SOR.
Mean retinal sensitivity increased in 100% patients (20/20) after SOR with a mean value of 97.44 dB. Best-corrected visual acuity after SOR remained unchanged in 90% (18/20) and improved by 2 lines in only 10% patients (2/20). Median retinal sensitivity of central 6° of the macula was 766.95 ± 173.29 dB before SOR and 863.8 ± 181.08 dB after SOR, P < 0.0001. Mean best-corrected visual acuity was 20/40 before SOR (range, 20/30-20/60) (logarithm of the minimum angle of resolution 0.314 ± 0.169) and 20/40 after SOR (range 20/30-20/80) (logarithm of the minimum angle of resolution 0.315 ± 0.159), P = 0.1628.
MP3 was found to be a highly sensitive tool in detecting increased retinal sensitivity after SOR, particularly in central 6° of the macula without significant change in best-corrected visual acuity. Hence, MP3 is an important qualitative indicator of visual function.
评估硅油取出(SOR)前后黄斑区的功能变化,使用微视野计(MP3)对黄斑脱离的孔源性视网膜脱离患者进行研究。
前瞻性干预研究,N = 20。所有病例均行全面眼科检查,包括最佳矫正视力的 Snellen 视力、间接检眼镜和 MP3 测量视网膜敏感度。主要观察指标为描述 SOR 后黄斑区视网膜敏感度的变化。
SOR 后 100%(20/20)的患者视网膜敏感度增加,平均数值为 97.44 dB。90%(18/20)的患者 SOR 后最佳矫正视力保持不变,仅 10%(2/20)的患者提高 2 行。SOR 前黄斑中心 6°的中位数视网膜敏感度为 766.95 ± 173.29 dB,SOR 后为 863.8 ± 181.08 dB,P < 0.0001。SOR 前最佳矫正视力为 20/40(范围 20/30-20/60)(最小分辨角对数 0.314 ± 0.169),SOR 后为 20/40(范围 20/30-20/80)(最小分辨角对数 0.315 ± 0.159),P = 0.1628。
MP3 是一种检测 SOR 后视网膜敏感度增加的高度敏感工具,特别是在黄斑中心 6°,而最佳矫正视力无明显变化。因此,MP3 是一种重要的视觉功能定性指标。