使用环形网格投影对日抛型隐形眼镜镜片前泪膜稳定性的主观比较

Subjective Comparison of Pre-Lens Tear Film Stability of Daily Disposable Contact Lenses Using Ring Mire Projection.

作者信息

Müller Christiane, Marx Sebastian, Wittekind Julia, Sickenberger Wolfgang

机构信息

Jenalens Kontaktlinsenstudio GmbH, Jena, Germany.

JenVis Research c/o Ernst-Abbe University of Applied Sciences Jena, Jena, Germany.

出版信息

Clin Optom (Auckl). 2020 Feb 28;12:17-26. doi: 10.2147/OPTO.S235167. eCollection 2020.

Abstract

PURPOSE

To subjectively evaluate the in vivo tear film stability of three daily disposable contact lenses (DDCLs) using placido ring reflection at lens wear times of 5 mins and 8 and 12 hrs.

PATIENTS AND METHODS

This prospective, randomized, observer-masked, 3-way crossover study evaluated 28 subjects with good tear film stability. In vivo tear film stability was assessed for three DDCLs (nelfilcon A, etafilcon A, omafilcon A) on three different days over 12 hrs of lens wear. Time to first distortion by non-invasive keratography drying-up time (NIK-DUT) was assessed by reviewing the captured videos. Lens wettability was also graded subjectively by three investigators using a scale from 0 (no visible distortions) to 3 (distortions in more than one-third of the ring reflection zone). Medians were analyzed statistically.

RESULTS

Mean NIKDUT at 8 hrs was longer for nelfilcon A and shorter for etafilcon A and omafilcon A, but the differences were not significant. NIK-DUT did not differ significantly among nelfilcon A, etafilcon A and omafilcon A DDCLs at all visits (p=0.36). Subjective wettability grades after 5 mins, 8 hrs, and 12 hrs differed significantly for etafilcon A ( <0.01) and omafilcon A ( < 0.01), but not for nelfilcon A ( = 0.05), DDCLs.

CONCLUSION

Grading was sufficiently sensitive to differentiate the wettability performances of the three lens materials. Nelfilcon A maintained wettability over the wearing period, whereas etafilcon A material showed faster dewetting at 8 and 12 hrs than at 5 mins after lens insertion.

摘要

目的

使用普拉西多环反射法,在佩戴隐形眼镜5分钟、8小时和12小时时,主观评估三种日抛型隐形眼镜(DDCL)在体内的泪膜稳定性。

患者与方法

这项前瞻性、随机、观察者盲法、三交叉研究评估了28名泪膜稳定性良好的受试者。在佩戴隐形眼镜12小时的三天内,对三种DDCL(奈非康A、依他康A、奥马菲康A)的体内泪膜稳定性进行了评估。通过查看拍摄的视频,评估首次出现非侵入性角膜地形图干燥时间(NIK-DUT)变形的时间。三位研究者还使用从0(无可见变形)到3(超过三分之一的环反射区出现变形)的量表对镜片的润湿性进行主观分级。对中位数进行统计学分析。

结果

奈非康A在8小时时的平均NIKDUT较长,依他康A和奥马菲康A较短,但差异不显著。在所有就诊时,奈非康A、依他康A和奥马菲康A DDCL之间的NIK-DUT没有显著差异(p=0.36)。依他康A(<0.01)和奥马菲康A(<0.01)在5分钟、8小时和12小时后的主观润湿性分级有显著差异,但奈非康A DDCL没有(=0.05)。

结论

分级对区分三种镜片材料的润湿性表现具有足够的敏感性。奈非康A在佩戴期间保持了润湿性,而依他康A材料在镜片插入后8小时和12小时的去湿速度比5分钟时更快。