Marx Sebastian, Eckstein Julia, Sickenberger Wolfgang
JENVIS Research c/o Ernst-Abbe University of Applied Sciences Jena, Jena, Germany.
Department of Optometry & Vision Science, Ernst-Abbe University of Applied Sciences Jena, Jena, Germany.
Clin Optom (Auckl). 2020 Nov 20;12:203-211. doi: 10.2147/OPTO.S262353. eCollection 2020.
The primary objective of this study was to evaluate the in vivo pre-lens non-invasive drying-up time of two types of daily disposable contact lenses (DDCLs) after 12 hours of wear.
This prospective, randomized, single-center, cross-over pilot study evaluated 31 subjects aged 18-44 years with normal eyes and good tear film stability who were adapted current soft contact lens wearers. Subjects wore nelfilcon A and stenfilcon A DDCLs for 12 hours each on two different days. Non-invasive video keratography drying-up time (NIK-DUT) videos of each eye were recorded 12 hours after lens insertion for about 25 seconds, with a 5-minute tear film recovery time allowed between video recordings of the right and left eyes to avoid bias. Post-blink time required to reach 15% distortion of the projected rings and the speed of break-up at 15 seconds post-blink were measured at each time point and on-eye wettability was determined by ring mire projection under white light illumination.
Mean time to reach 15% ring distortion was similar for nelfilcon A (19.25±3.20 sec) and stenfilcon A (20.24±3.02 sec) DDCLs but varied highly among subjects. The mean speed of break-up at 15 sec post-blink was 0.3±0.38% distortion/sec (95% confidence interval [CI] 0.138-0.365% distortion/sec) for nelfilcon A and 0.2±0.23% distortion/sec (95% CI 0.048-0.279% distortion/sec) for stenfilcon A DDCLs.
Multifunctional topography allowed the objective evaluation of in vivo pre-lens tear film stability using ring mire projection. This dynamic method was simple, fast and non-invasive, enabling measurements of NIK-DUT and evaluating wettability over a large area, greater than the optical zone of the contact lens surface, for the entire inter-blink interval.
本研究的主要目的是评估两种日抛型隐形眼镜(DDCLs)佩戴12小时后在体内的镜片前非侵入性干燥时间。
这项前瞻性、随机、单中心、交叉试点研究评估了31名年龄在18 - 44岁、眼睛正常且泪膜稳定性良好的受试者,他们均为现有的软性隐形眼镜佩戴者。受试者在两天内分别佩戴奈非康A和司替康A日抛型隐形眼镜各12小时。在镜片插入12小时后,对每只眼睛进行非侵入性视频角膜造影干燥时间(NIK - DUT)视频记录约25秒,左右眼视频记录之间允许5分钟的泪膜恢复时间以避免偏差。在每个时间点测量达到投射环15%变形所需的眨眼后时间以及眨眼后15秒时的破裂速度,并通过白光照明下的环形视标投影确定眼表润湿性。
奈非康A(19.25±3.20秒)和司替康A(20.24±3.02秒)日抛型隐形眼镜达到15%环变形的平均时间相似,但个体差异很大。奈非康A日抛型隐形眼镜眨眼后15秒时的平均破裂速度为0.3±0.38%变形/秒(95%置信区间[CI] 0.138 - 0.365%变形/秒),司替康A日抛型隐形眼镜为0.2±0.23%变形/秒(95% CI 0.048 - 0.279%变形/秒)。
多功能地形图通过环形视标投影实现了对体内镜片前泪膜稳定性的客观评估。这种动态方法简单、快速且非侵入性,能够测量NIK - DUT并在整个眨眼间隔内评估大于隐形眼镜光学区表面的大面积润湿性。