Collection efficiencies of four bioaerosol samplers (Andersen impactor, AGI-30 impinger, gelatin filter, and nuclepore filter) were evaluated for virus-containing aerosols. Four different bacteriophages were used as surrogates for the mammalian viruses. Results showed that the collection efficiency was significantly affected by the morphology of the virus particles. For hydrophilic viruses, the collection efficiencies of the Andersen impactor, impinger, and gelatin filter were 10 times higher than that of the nuclepore filter. For hydrophilic viruses, the collection efficiencies of all four samplers were 10-100 times higher than hydrophobic viruses. The infectivity of the virus in collected samples was also evaluated for an AGI-30 impinger. Results showed that the viruses retained more infectivity when the samples were refrigerated (up to 1 day) during storage than when stored at room temperature (up to 8 h). Therefore, even when refrigerated, airborne virus samples collected using an impinger should be processed as soon as possible to avoid loss of virus infectivity.

摘要

评估了四种生物气溶胶采样器(安德森撞击式采样器、AGI-30冲击式采样器、明胶滤膜和核孔滤膜)对含病毒气溶胶的采集效率。使用四种不同的噬菌体作为哺乳动物病毒的替代物。结果表明,采集效率受病毒颗粒形态的显著影响。对于亲水性病毒,安德森撞击式采样器、冲击式采样器和明胶滤膜的采集效率比核孔滤膜高10倍。对于亲水性病毒,所有四种采样器的采集效率比疏水性病毒高10至100倍。还对AGI-30冲击式采样器采集样本中的病毒感染性进行了评估。结果表明,与在室温下(最长8小时)储存相比,样本在冷藏(最长1天)储存期间病毒保留了更多的感染性。因此,即使冷藏,使用冲击式采样器采集的空气传播病毒样本也应尽快处理,以避免病毒感染性丧失。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8613/7118727/3eaec2fff060/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验