Istituto Giuseppe Cozzani, La Spezia, Italy.
Dental School, Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy.
Int Orthod. 2020 Sep;18(3):503-508. doi: 10.1016/j.ortho.2020.03.003. Epub 2020 May 6.
The miniscrew is effectively used to provide additional anchorage for orthodontic purposes. The aim of this study was to identify an optimal insertion angle for Jeil, Storm, and Thunder miniscrews on stress distribution at the bone miniscrew interface.
To perform 3-dimensional finite element model analysis, a 3-dimensional model with a bone block was constructed with type D2 of bone quality, and with miniscrews of Storm, Thunder, Jeil, with the diameter of 2, 1.5. 1.6mm and length 15.9, 12.4, 14.4mm respectively. The miniscrews were inserted at 15° 30°, 45°, 60°, 75° and 90° to the bone surface. A simulated horizontal orthodontic force of 200 gram was applied to the centre of the miniscrews head in all models, and stress distribution and its magnitude were evaluated with a 3-dimensional finite element analysis program.
In the cancellous bone, minimum stress was found at placement angles of 90° for Jeil and Storm, which was 0.37 and 0.39MPa respectively, and 15° for Thunder, which was 0.85MPa. The maximum von Mises stresses in the cancellous bone for Jeil was at 60°, which was 0.92MPa, and for Thunder at 90°, which was 1.3MPa.
Each miniscrew has an ideal insertion angle, optimal insertion positions were found within 90° for Jeil and for Storm but 15° for Thunder. Clinical significance 3-dimensional finite element analysis confirmed that each miniscrew has an ideal insertion angle according to its characteristics.
微型种植钉有效地用于提供正畸的额外锚固。本研究旨在确定 Jeil、Storm 和 Thunder 微型种植钉在骨-种植钉界面的应力分布方面的最佳植入角度。
为了进行三维有限元模型分析,构建了具有骨质量类型 D2 的骨块三维模型,并分别使用直径为 2、1.5、1.6mm 且长度为 15.9、12.4、14.4mm 的 Storm、Thunder、Jeil 微型种植钉。微型种植钉以 15°、30°、45°、60°、75°和 90°的角度插入到骨表面。在所有模型中,在微型种植钉头部的中心施加模拟的 200 克水平正畸力,并使用三维有限元分析程序评估应力分布及其大小。
在松质骨中,Jeil 和 Storm 的最小应力出现在 90°的植入角度,分别为 0.37 和 0.39MPa,而 Thunder 的最小应力出现在 15°,为 0.85MPa。在松质骨中,Jeil 的最大 von Mises 应力出现在 60°,为 0.92MPa,而 Thunder 的最大 von Mises 应力出现在 90°,为 1.3MPa。
每种微型种植钉都有一个理想的植入角度,Jeil 和 Storm 的最佳植入位置在 90°以内,但 Thunder 则为 15°。临床意义三维有限元分析证实,根据每种微型种植钉的特点,都有一个理想的植入角度。