Suppr超能文献

荧光辅助去除正畸复合材料:一项体内对比研究。

Fluorescence-aided removal of orthodontic composites: an in vivo comparative study.

机构信息

Postgraduate School of Orthodontics, University of Ferrara, Via Livatino, 9, 42124, Reggio Emilia, Italy.

出版信息

Prog Orthod. 2022 May 23;23(1):16. doi: 10.1186/s40510-022-00411-w.

Abstract

BACKGROUND

To compare the fluorescent properties of 6 different orthodontic adhesives and provide useful information for clinicians in the adhesion choice, in order to remove it easily at the end of orthodontic treatment by using the Fluorescence-aided Identification Technique (FIT).

METHODS

Six orthodontic adhesives were included: Ortho Connect, Gradia LoFlo A3.5, Greengloo, Transbond XT, KommonBase Pink, and KommonBase Clear. The same thermoformed template with 1 mm shell thickness on the six anterior teeth was used for adhesive positioning; furthermore, an ultraviolet light-emitting diode flashlight was used for the FIT. The brightness of adhesive area and tooth area (L* color coordinate) were measured on the photographs by using the "color picker" tool of Photoshop software.

RESULTS

GC Ortho Connect, Gradia Direct LoFlo and KommonBase Clear showed the highest differences of brightness (15.5, 16.3 and 13.5, respectively), while Greengloo, Transbond XT and KommonBase Pink registered similar values between resin area and tooth area with FIT (- 0.5, - 0.8 and - 1.0, respectively). The high viscosity adhesive resins, as Greengloo and Transbond XT, showed a similar performance in terms of fluorescence to the KommonBase Pink, the lowest viscous resin adhesive considered.

CONCLUSIONS

The most used orthodontic adhesives showed different fluorescence properties. Some resins were brighter with the FIT, facilitating identification and subsequent removal. Other orthodontic adhesives presented no difference between adhesive and tooth. The viscosity of orthodontic adhesives did not influence the brightness emitted with FIT.

摘要

背景

为了比较 6 种不同正畸粘接剂的荧光性能,为临床医生在粘接选择中提供有用的信息,以便在正畸治疗结束时使用荧光辅助识别技术(FIT)轻松去除。

方法

纳入了 6 种正畸粘接剂:Ortho Connect、Gradia LoFlo A3.5、Greengloo、Transbond XT、KommonBase Pink 和 KommonBase Clear。在 6 颗前牙上使用相同的热成型模板,厚度为 1mm,用于粘接剂定位;此外,使用紫外线发光二极管手电筒进行 FIT。使用 Photoshop 软件的“颜色选择器”工具测量照片上粘接剂区域和牙齿区域的亮度(L*颜色坐标)。

结果

GC Ortho Connect、Gradia Direct LoFlo 和 KommonBase Clear 的亮度差异最大(分别为 15.5、16.3 和 13.5),而 Greengloo、Transbond XT 和 KommonBase Pink 在 FIT 下树脂区域和牙齿区域之间的差值相似(分别为-0.5、-0.8 和-1.0)。高粘度粘接树脂,如 Greengloo 和 Transbond XT,在荧光性能方面与 KommonBase Pink 表现相似,后者是粘性最低的树脂粘接剂。

结论

最常用的正畸粘接剂表现出不同的荧光性能。一些树脂在 FIT 下更亮,便于识别和后续去除。其他正畸粘接剂在粘接剂和牙齿之间没有差异。正畸粘接剂的粘度不影响 FIT 发出的亮度。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c3fc/9124738/a9db42547743/40510_2022_411_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验