Krafft Paul R, Osburn Brooks, Vivas Andrew C, Rao Gautam, Alikhani Puya
Department of Neurosurgery and Brain Repair, Morsani College of Medicine, University of South Florida, Tampa, USA.
Spine Surg Relat Res. 2019 Dec 20;4(2):171-177. doi: 10.22603/ssrr.2019-0089. eCollection 2020.
Implant subsidence is a potential complication of spinal interbody fusion and may negatively affect patients subjected to procedures relying on indirect decompression such as minimally invasive transpsoas lateral lumbar interbody fusion (LLIF). The porous architecture of a recently developed titanium intervertebral cage maximizes bone-to-implant contact and minimizes stress shielding in laboratory experiments; however, its subsidence rate in patients has not yet been evaluated. The goal of this current study was to evaluate implant subsidence in patients subjected to LLIF.
Our institutional review board-approved single-center experience included 29 patients who underwent 30 minimally invasive LLIF from July 2017 to September 2018 utilizing the novel 3D-printed porous titanium implants. Radiographs, obtained during routine postoperative follow-up visits, were reviewed for signs of implant subsidence, defined as any appreciable compromise of the vertebral endplates.
Radiographic subsidence occurred in 2 cases (6.7%), involving 2 out of 59 porous titanium interbody cages (3.4%). Both cases of subsidence occurred in four-level stand-alone constructs. The patients remained asymptomatic and did not require surgical revision. Ten surgeries were stand-alone constructs, and 20 surgeries included supplemental posterior fixation.
In our patient cohort, subsidence of the porous titanium intervertebral cage occurred in 6.7% of all cases and in 3.4% of all lumbar levels. This subsidence rate is lower compared to previously reported subsidence rates in patients subjected to LLIF using polyetheretherketone implants.
植入物下沉是脊柱椎间融合术的一种潜在并发症,可能会对依赖间接减压的手术患者产生负面影响,如微创经腰大肌外侧腰椎椎间融合术(LLIF)。最近开发的一种钛椎间融合器的多孔结构在实验室实验中可使骨与植入物的接触最大化,并使应力遮挡最小化;然而,其在患者中的下沉率尚未得到评估。本研究的目的是评估接受LLIF手术患者的植入物下沉情况。
我们机构审查委员会批准的单中心经验包括29例患者,他们在2017年7月至2018年9月期间接受了30例使用新型3D打印多孔钛植入物的微创LLIF手术。对术后常规随访期间获得的X线片进行审查,以寻找植入物下沉的迹象,植入物下沉定义为椎体终板出现任何明显的受损情况。
X线片显示有2例(6.7%)出现下沉,涉及59个多孔钛椎间融合器中的2个(3.4%)。两例下沉均发生在四级独立结构中。患者仍无症状,无需手术翻修。10例手术为独立结构,20例手术包括补充后路固定。
在我们的患者队列中,多孔钛椎间融合器下沉在所有病例中占6.7%,在所有腰椎节段中占3.4%。与先前报道的使用聚醚醚酮植入物进行LLIF手术患者的下沉率相比,该下沉率较低。