Suppr超能文献

某中国高校教室、宿舍和食堂室内环境中可培养空气传播细菌的评估:一项案例研究

Assessment of culturable airborne bacteria of indoor environments in classrooms, dormitories and dining hall at university: a case study in China.

作者信息

Li Yanju, Ge Yanhui, Wu Chunbin, Guan Dexing, Liu Jinbao, Wang Fuyang

机构信息

School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin, China.

School of Environmental Science and Safety Engineering, Tianjin University of Technology, Tianjin, China.

出版信息

Aerobiologia (Bologna). 2020;36(3):313-324. doi: 10.1007/s10453-020-09633-z. Epub 2020 Mar 2.

Abstract

University students' health may be adversely affected by exposure to indoor bacterial contaminants on their campuses. This study aims (1) to quantify culturable bacterial concentrations in three indoor environments at a university, (2) to investigate the influence of meteorological factors and gender, to assess the relationship between indoor and outdoor, and (3) to estimate the bacterial dose for university students in different indoor environments. Airborne bacteria samples were collected in 12 classrooms, in 12 living rooms and four bathrooms in two dormitory buildings, and in a dining hall. The results showed that the microenvironment in the female dormitory had the highest mean bacterial concentration (2847 CFU/m), whereas the lowest mean bacterial concentration was observed in classrooms (162 CFU/m). Indoor bacterial concentrations in male dormitories were significantly lower than in female dormitories probably because of crowding and increased ventilation. Outdoor weather conditions were associated with the indoor concentrations with regard to insufficient ventilation and varying outdoor concentration. The occupants' activity level was also more closely related to the indoor bacteria concentration in the residential setting. Students experienced about four times higher dose of airborne bacteria in the dormitories than in the classrooms and dining hall.

摘要

大学生接触校园内的室内细菌污染物可能会对其健康产生不利影响。本研究旨在:(1)量化某大学三种室内环境中的可培养细菌浓度;(2)调查气象因素和性别的影响,评估室内外之间的关系;(3)估算不同室内环境中大学生的细菌接触量。在两栋宿舍楼的12间教室、12间起居室、4间浴室以及一个食堂中采集了空气传播细菌样本。结果显示,女生宿舍的微环境平均细菌浓度最高(2847 CFU/m),而教室中的平均细菌浓度最低(162 CFU/m)。男生宿舍的室内细菌浓度显著低于女生宿舍,这可能是由于拥挤和通风增加所致。在通风不足和室外浓度变化方面,室外天气状况与室内浓度相关。居住环境中,居住者的活动水平也与室内细菌浓度关系更为密切。学生在宿舍接触到的空气传播细菌剂量比在教室和食堂中高出约四倍。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/71f8/7223800/7c854caf3107/10453_2020_9633_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验