Abstract

This article studies the relationship between two metrics, the area under the modulation transfer function (MTFa) and the energy efficiency (EE), and their ability to predict the visual quality of patients implanted with multifocal intraocular lenses (IOLs). The optical quality of IOLs is assessed in vitro using two metrics, the MTFa and EE. We measured them for three different multifocal IOLs with parabolic phase profile using image formation, through-focus (TF) scanning, three R, G, B wavelengths, and two pupils. We analyzed the correlation between MTFa and EE. In parallel, clinical defocus curves of visual acuity (VA) were measured and averaged from sets of patients implanted with the same IOLs. An excellent linear correlation was found between the MTFa and EE for the considered IOLs, wavelengths and pupils (R > 0.9). We computed the polychromatic TF-MTFa, TF-EE, and derived mathematical relationships between each metrics and clinical average VA. MTFa and EE proved to be equivalent metrics to characterize the optical quality of the studied multifocal IOLs and also in terms of clinical VA predictability.

摘要

本文研究了调制传递函数下的面积(MTFa)和能量效率(EE)这两个指标之间的关系,以及它们预测植入多焦点人工晶状体(IOL)患者视觉质量的能力。使用MTFa和EE这两个指标在体外评估IOL的光学质量。我们通过成像、全聚焦(TF)扫描、三个R、G、B波长和两个瞳孔,对三种具有抛物线相位分布的不同多焦点IOL进行了测量。我们分析了MTFa与EE之间的相关性。同时,对植入相同IOL的患者组测量并平均了视力(VA)的临床散焦曲线。在所考虑的IOL、波长和瞳孔方面,MTFa与EE之间发现了极好的线性相关性(R > 0.9)。我们计算了多色TF-MTFa、TF-EE,并推导了每个指标与临床平均VA之间的数学关系。MTFa和EE被证明是表征所研究多焦点IOL光学质量以及临床VA可预测性方面的等效指标。

相似文献

1
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients.
Biomed Opt Express. 2020 Apr 30;11(5):2818-2829. doi: 10.1364/BOE.388531. eCollection 2020 May 1.
2
Visual acuity of pseudophakic patients predicted from measurements of intraocular lenses with different design.
Biomed Opt Express. 2018 Sep 17;9(10):4893-4906. doi: 10.1364/BOE.9.004893. eCollection 2018 Oct 1.
3
Spatio-chromatic vision with multifocal diffractive intraocular lens.
Eye Vis (Lond). 2023 Aug 1;10(1):32. doi: 10.1186/s40662-023-00350-5.
4
Preclinical metrics to predict through-focus visual acuity for pseudophakic patients.
Biomed Opt Express. 2016 Apr 15;7(5):1877-88. doi: 10.1364/BOE.7.001877. eCollection 2016 May 1.
5
Prediction of Visual Acuity and Contrast Sensitivity From Optical Simulations With Multifocal Intraocular Lenses.
J Refract Surg. 2019 Dec 1;35(12):789-795. doi: 10.3928/1081597X-20191024-01.
6
[Impact of Near Addition on the Optical Quality of Diffractive Multifocal Intraocular Lenses - a Laboratory Study Using an Optical Bench].
Klin Monbl Augenheilkd. 2017 Dec;234(12):1533-1539. doi: 10.1055/s-0043-112860. Epub 2017 Oct 12.
7
Longitudinal Chromatic Aberration and Polychromatic Image Quality Metrics of Intraocular Lenses.
J Refract Surg. 2018 Dec 1;34(12):832-838. doi: 10.3928/1081597X-20181108-01.
9
Visual acuity and image quality in 5 diffractive intraocular lenses.
Eur J Ophthalmol. 2018 Jan;28(1):36-41. doi: 10.5301/ejo.5000994.
10
Far and near visual acuity with multifocal intraocular lenses in an optomechanical eye model with imaging capability.
J Cataract Refract Surg. 2007 Jun;33(6):1082-94. doi: 10.1016/j.jcrs.2007.01.028.

引用本文的文献

1
Improving the estimation of the spherical equivalent subjective refraction using objective information on accommodation.
Biomed Opt Express. 2025 Jul 16;16(8):3194-3205. doi: 10.1364/BOE.562636. eCollection 2025 Aug 1.
2
Comparison of optical performances of intraocular lenses with different depth of field.
J Optom. 2025 Apr-Jun;18(2):100546. doi: 10.1016/j.optom.2025.100546. Epub 2025 Mar 29.
3
Prediction of monocular defocus curves in pseudophakia with different pupil sizes.
Biomed Opt Express. 2025 Jan 28;16(2):709-717. doi: 10.1364/BOE.540583. eCollection 2025 Feb 1.
4
Silver mean sequence in extended depth of focus intraocular lenses: a comparative study of kinoform and stepwise designs.
Biomed Opt Express. 2024 Nov 26;15(12):6999-7012. doi: 10.1364/BOE.540754. eCollection 2024 Dec 1.
5
Impact of pupil size and corneal spherical aberrations on the performance of monofocal intraocular lenses: an experimental model.
Biomed Opt Express. 2024 Oct 21;15(11):6433-6448. doi: 10.1364/BOE.530708. eCollection 2024 Nov 1.
6
Optical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design.
Graefes Arch Clin Exp Ophthalmol. 2024 Dec;262(12):3905-3913. doi: 10.1007/s00417-024-06590-y. Epub 2024 Jul 24.
7
Fabrication and performance evaluation of a design for an extended depth-of-focus intraocular lens based on an improved sinusoidal profile.
Biomed Opt Express. 2024 May 24;15(6):3932-3949. doi: 10.1364/BOE.521105. eCollection 2024 Jun 1.
8
Fourier tools for the evaluation of refractive multifocal designs.
Sci Rep. 2023 Dec 19;13(1):22585. doi: 10.1038/s41598-023-50172-7.
9
Spatio-chromatic vision with multifocal diffractive intraocular lens.
Eye Vis (Lond). 2023 Aug 1;10(1):32. doi: 10.1186/s40662-023-00350-5.
10
Optical performance of a new design of a trifocal intraocular lens based on the Devil's diffractive lens.
Biomed Opt Express. 2023 Apr 28;14(5):2365-2374. doi: 10.1364/BOE.487812. eCollection 2023 May 1.

本文引用的文献

1
Prediction of Visual Acuity and Contrast Sensitivity From Optical Simulations With Multifocal Intraocular Lenses.
J Refract Surg. 2019 Dec 1;35(12):789-795. doi: 10.3928/1081597X-20191024-01.
2
Topography and longitudinal chromatic aberration characterizations of refractive-diffractive multifocal intraocular lenses.
J Cataract Refract Surg. 2019 Nov;45(11):1650-1659. doi: 10.1016/j.jcrs.2019.06.002. Epub 2019 Oct 1.
3
The Effect of a Spectral Filter on Visual Quality in Patients with an Extended-Depth-Of-Focus Intraocular Lens.
Am J Ophthalmol. 2019 Dec;208:56-63. doi: 10.1016/j.ajo.2019.07.001. Epub 2019 Jul 16.
4
Visual acuity of pseudophakic patients predicted from measurements of intraocular lenses with different design.
Biomed Opt Express. 2018 Sep 17;9(10):4893-4906. doi: 10.1364/BOE.9.004893. eCollection 2018 Oct 1.
5
Patient-Perceived and Laboratory-Measured Halos Associated with Diffractive Bifocal and Trifocal Intraocular Lenses.
Curr Eye Res. 2018 Jan;43(1):35-42. doi: 10.1080/02713683.2017.1379541. Epub 2017 Nov 21.
6
Extended depth of focus intraocular lens: Chromatic performance.
Biomed Opt Express. 2017 Aug 31;8(9):4294-4309. doi: 10.1364/BOE.8.004294. eCollection 2017 Sep 1.
7
Visual acuity and image quality in 5 diffractive intraocular lenses.
Eur J Ophthalmol. 2018 Jan;28(1):36-41. doi: 10.5301/ejo.5000994.
8
Preclinical metrics to predict through-focus visual acuity for pseudophakic patients.
Biomed Opt Express. 2016 Apr 15;7(5):1877-88. doi: 10.1364/BOE.7.001877. eCollection 2016 May 1.
10
Clinically Relevant Optical Properties of Bifocal, Trifocal, and Extended Depth of Focus Intraocular Lenses.
J Refract Surg. 2016 Apr;32(4):273-80. doi: 10.3928/1081597X-20160121-07.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验