Suppr超能文献

带内移龙骨的膝关节置换系统:先驱队列的七年随访

Knee arthroplasty system with medialized keel: Seven-year follow-up of a pioneer cohort.

作者信息

Benazzo F, Jannelli E, Ivone A, Formagnana M, Rossi S M, Ghiara M, Danesino G, Mosconi M

机构信息

Department of Clinical-Surgical Sciences, Diagnostics and Pediatrics, University of Pavia, Operative Unit of Orthopaedics and Traumatology, Fondazione IRCCS Policlinico San Matteo, Via Golgi, 19, 27100, Pavia, Italy.

Department of Clinical-Surgical Sciences, Diagnostics and Pediatrics, University of Pavia, Operative Unit of Orthopaedics and Traumatology, Fondazione IRCCS Policlinico San Matteo, Via Golgi, 19, 27100, Pavia, Italy.

出版信息

Knee. 2020 Jun;27(3):624-632. doi: 10.1016/j.knee.2020.04.014. Epub 2020 Apr 30.

Abstract

BACKGROUND

In this clinical investigation, a new design with a progressive increased keel medialization according to the size was implanted. The cohort of patients was followed up for seven years.

METHODS

From May 2012 to November 2012, we implanted 70 total knee arthroplasties in 69 patients. The mean age of the patients was 76.2 years. We followed up 56 patients for seven years; we evaluated the patients at six and 60 months after surgery by Patient Reported Outcome Measures score. During the seven-year follow-up, all patients were clinically re-evaluated using the Knee Society Score and the Forgotten Joint Score. All patients underwent a preoperative and postoperative radiographic investigation. At the last follow-up the presence of any radiolucency lines was checked using the Knee Society Total Knee Arthroplasty Radiographic Evaluation and Scoring System.

RESULTS

The patients defined the surgical results as excellent in 66% of the cases, very good in 23%, good in five percent. The analysis of the functional data at seven years, performed by administering the Forgotten Joint Score, showed average values of 70.4. The clinical analysis, performed through the Knee Society Score at the same follow-up, showed average values of 90.4. The seven-year radiological analysis revealed the presence of radiolucency lines in 20 implants. The sum of the line widths never exceeded the critical value of nine millimeters, always remaining below four millimeters. Only one patient was revised.

CONCLUSIONS

The results showed an excellent outcome of this design. The medialization of the tibial keel showed good bone fixation and component alignment at seven-year follow-up.

摘要

背景

在这项临床研究中,植入了一种根据尺寸逐渐增加龙骨向内侧移位的新设计。对该队列患者进行了七年的随访。

方法

2012年5月至2012年11月,我们为69例患者植入了70个全膝关节置换术。患者的平均年龄为76.2岁。我们对56例患者进行了七年的随访;我们在术后6个月和60个月通过患者报告结局测量评分对患者进行评估。在七年的随访期间,所有患者均使用膝关节协会评分和遗忘关节评分进行临床重新评估。所有患者均接受术前和术后影像学检查。在最后一次随访时,使用膝关节协会全膝关节置换术影像学评估和评分系统检查是否存在任何透光线。

结果

66%的患者将手术结果定义为优秀,23%为非常好,5%为好。通过应用遗忘关节评分对七年的功能数据进行分析,显示平均值为70.4。在同一随访中通过膝关节协会评分进行的临床分析显示平均值为90.4。七年的放射学分析显示20个植入物中存在透光线。线宽总和从未超过9毫米的临界值,始终保持在4毫米以下。只有一名患者进行了翻修。

结论

结果显示该设计效果极佳。在七年的随访中,胫骨龙骨的向内侧移位显示出良好的骨固定和假体对线。