光动力疗法对不同根管内三分之一牙本质的 MTA 根管封闭剂粘结强度和粘结界面形态的影响。

Influence of photodynamic therapy on bond strength and adhesive interface morphology of MTA based root canal sealer to different thirds of intraradicular dentin.

机构信息

Department of Preventive and Restorative Dentistry, Discipline of Endodontics, Araçatuba School of Dentistry, São Paulo State University - UNESP, Araçatuba, SP, Brazil.

Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University - UNESP, Araçatuba, SP, Brazil.

出版信息

Photodiagnosis Photodyn Ther. 2020 Dec;32:102031. doi: 10.1016/j.pdpdt.2020.102031. Epub 2020 Oct 1.

Abstract

BACKGROUND

Photodynamic therapy (PDT) is used as an adjunct to endodontic treatment to enhance microbial reduction in the root canal system. However, studies evaluating the impact of PDT on the bond strength of the canal sealer to intraradicular dentin are scarce. Thus, this in vitro study aimed to evaluate the influence of photodynamic therapy with methylene blue (MB) photosensitizer (PS) on the bond strength and morphology of the interface between mineral trioxide aggregate (MTA) based endodontic sealer and different thirds of intraradicular dentin.

METHODS

Fifty-five bovine incisors were used to simulate experimental endodontic treatments. Biomechanical instrumentation was performed in all root canals and teeth were divided into 5 groups (n = 11): deionized water (control), methylene blue 50 mg/L (MB), methylene blue 100 mg/L (MB), methylene blue 50 mg/L + red laser (MB), and methylene blue 100 mg/L + red laser (MB). The push-out bond strength of canal sealer to intraradicular dentin was measured using a universal testing machine (n = 8). Representative scanning electron microscopy images were obtained to qualify the fracture patterns. Images of the adhesive interface morphology were obtained using confocal laser scanning microscopy (n = 3). The Kruskal-Wallis test was used to compare data on bond strength between groups, and the Friedman test between thirds (α = 0.05).

RESULTS

When comparing root thirds for the MB group with the higher concentration activated by red laser, higher bond strength values was found for the apical third than for the middle third (P = 0.0302). MB in different concentrations, activated by red laser or not, had no influence on the bond strength of distinct thirds of the intraradicular dentin (P > 0.05). As for the adhesive interface morphology, the MB group showed a lower qualitatively sealer penetration into the intraradicular dentin.

CONCLUSIONS

PDT with MB PS at 50 mg/L had no negative impact on the bond strength of MTA Fillapex canal sealer to intraradicular dentin, being a suitable antisepsis protocol for endodontic treatments.

摘要

背景

光动力疗法(PDT)被用作牙髓治疗的辅助手段,以增强根管系统中的微生物减少。然而,评估 PDT 对根管封闭剂与根管内牙本质之间粘结强度影响的研究很少。因此,本体外研究旨在评估亚甲蓝(MB)光敏剂(PS)的光动力疗法对基于三氧化矿物凝聚体(MTA)的根管封闭剂与根管内牙本质不同部位之间界面粘结强度和形态的影响。

方法

使用 55 颗牛切牙模拟实验性牙髓治疗。所有根管均进行生物力学器械处理,将牙齿分为 5 组(n=11):去离子水(对照)、亚甲蓝 50mg/L(MB)、亚甲蓝 100mg/L(MB)、亚甲蓝 50mg/L+红光激光(MB)和亚甲蓝 100mg/L+红光激光(MB)。使用万能试验机测量根管封闭剂与根管内牙本质的推出粘结强度(n=8)。使用共聚焦激光扫描显微镜(n=3)获得代表性的扫描电子显微镜图像以定性断裂模式。获得粘结界面形态的图像使用共聚焦激光扫描显微镜(n=3)。使用 Kruskal-Wallis 检验比较各组间粘结强度数据,Friedman 检验比较根管内牙本质不同部位的数据(α=0.05)。

结果

当比较 MB 组中浓度较高的红光激光激活的根管第三部位时,根尖第三部位的粘结强度值高于中间第三部位(P=0.0302)。MB 以不同浓度存在,是否被红光激光激活,对根管内牙本质不同部位的粘结强度没有影响(P>0.05)。至于粘结界面形态,MB 组显示封闭剂向根管内牙本质的渗透程度较低。

结论

50mg/L MB PS 的 PDT 对 MTA Fillapex 根管封闭剂与根管内牙本质的粘结强度没有负面影响,是牙髓治疗的合适的消毒方案。