针对正常视力和低视力成年人的数字近视力阅读测试介绍:开发与验证
Introduction of a digital near-vision reading test for normal and low vision adults: development and validation.
作者信息
Labiris Georgios, Panagiotopoulou Eirini-Kanella, Chatzimichael Eleftherios, Tzinava Maria, Mataftsi Asimina, Delibasis Konstantinos
机构信息
Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68100 Alexandroupolis, Greece.
Department of Computer Science and Biomedical Informatics, University of Thessaly, 35100, Lamia, Greece.
出版信息
Eye Vis (Lond). 2020 Oct 22;7:51. doi: 10.1186/s40662-020-00216-0. eCollection 2020.
BACKGROUND
MNREAD is an advanced near-vision acuity chart that has already been translated and validated in Greek language. Considering that no validated Greek digital near-vision test exists, our primary objective was to develop and validate a digital near-vision reading test based on the fundamental properties of the Greek printed MNREAD (MNREAD-GR).
METHODS
This is a prospective, comparative study. A digital near-vision chart was developed (Democritus Digital Acuity Reading Test - DDART) with text size calibration, audio recording for automatic reading timing, as well as automatic calculation of reading acuity (RA), maximum reading speed (MRS), critical print size (CPS) and reading accessibility index (ACC). Normal and low vision subjects participated in the validation process, responding to MNREAD-GR and DDART at the same day, at a 40 cm viewing distance. Differences in all parameters between the charts were compared with t-test and intraclass correlation coefficients (ICCs). Within 15 days, all participants responded again to DDART in a different set of sentences to assess its test-retest reliability.
RESULTS
One hundred patients (normal vision group - NVG: 70 patients; low vision group - LVG: 30 patients) responded to both reading tests. Non-significant differences were detected for all parameters between DDART and MNREAD-GR except for MRS and ACC that were significantly higher in MNREAD-GR in NVG ( < 0.01). NVG participants demonstrated sufficient ICCs that ranged from 0.854 to 0.963, while LVG demonstrated ICCs for RA, ACC, MRS and CPS equal to 0.986, 0.894, 0.794 and 0.723, respectively. All parameters calculated with DDART demonstrated excellent test-retest reliability (ICCs: 0.903 - 0.956).
CONCLUSIONS
The proposed reading test presented comparable validity and repeatability to MNREAD-GR suggesting that it can be used both in normal and low vision Greek patients.
TRIAL REGISTRATION
ClinicalTrials.gov, NCT04242836. Registered 24 January 2020 - Retrospectively registered.
背景
MNREAD是一种先进的近视力视力表,已被翻译成希腊语并进行了验证。鉴于目前尚无经过验证的希腊语数字近视力测试,我们的主要目标是基于希腊语印刷版MNREAD(MNREAD-GR)的基本特性,开发并验证一种数字近视力阅读测试。
方法
这是一项前瞻性比较研究。我们开发了一种数字近视力表(德谟克利特数字视力阅读测试 - DDART),该视力表具有文本大小校准功能、用于自动读取时间的音频记录,以及自动计算阅读视力(RA)、最大阅读速度(MRS)、临界印刷字体大小(CPS)和阅读可达性指数(ACC)。正常视力和低视力受试者参与了验证过程,在40厘米的观看距离下,于同一天对MNREAD-GR和DDART进行测试。通过t检验和组内相关系数(ICC)比较两种视力表所有参数的差异。在15天内,所有参与者再次对DDART进行测试,测试内容为另一组句子,以评估其重测信度。
结果
100名患者(正常视力组 - NVG:70名患者;低视力组 - LVG:30名患者)参与了两项阅读测试。除MRS和ACC外,DDART和MNREAD-GR在所有参数上均未检测到显著差异,在NVG中,MNREAD-GR的MRS和ACC显著更高(<0.01)。NVG参与者的ICC值在0.854至0.963之间,表明具有足够的可靠性,而LVG的RA、ACC、MRS和CPS的ICC值分别为0.986、0.894、0.794和0.723。用DDART计算的所有参数均显示出优异的重测信度(ICC:0.903 - 0.956)。
结论
所提出的阅读测试与MNREAD-GR具有相当的效度和可重复性,这表明它可用于希腊正常视力和低视力患者。
试验注册
ClinicalTrials.gov,NCT04242836。于2020年1月24日注册 - 回顾性注册。