一种多维评估方法,用于评估移动应用程序与传统身体成分测定方法相比的收敛和同时效度。

A Multidomain Approach to Assessing the Convergent and Concurrent Validity of a Mobile Application When Compared to Conventional Methods of Determining Body Composition.

机构信息

Airway & Exercise Physiology Research Laboratory, David Geffen School of Medicine, Los Angeles, CA 90095, USA.

Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hofstra University, Hempstead, NY 11549, USA.

出版信息

Sensors (Basel). 2020 Oct 29;20(21):6165. doi: 10.3390/s20216165.

Abstract

Determining body composition via mobile application may circumvent limitations of conventional methods. However, the accuracy of many technologies remains unknown. This investigation assessed the convergent and concurrent validity of a mobile application (LS) that employs 2-dimensional digital photography (LS2D) and 3-dimensional photonic scanning (LS3D). Measures of body composition including circumferences, waist-to-hip ratio (WHR), and body fat percentage (BF%) were obtained from 240 healthy adults using LS and a diverse set of conventional methods-Gulick tape, bioelectrical impedance analysis (BIA), and skinfolds. Convergent validity was consistently high-indicating these methods vary proportionally and can thus reliably detect changes despite individual measurement differences. The span of the Limits of Agreement (LoA) using LS were comparable to the LoA between conventional methods. LS3D exhibited high agreement relative to Gulick tape in the measurement of WHR, despite poor agreement with individual waist and hip circumferences. In BF%, LS2D exhibited high agreement with BIA and skinfold methods, whereas LS3D demonstrated low agreement. Interestingly, the low inferred bias between LS3D and DXA using existing data suggests that LS3D may have high agreement with dual-energy x-ray absorptiometry. Overall, the suitability of LS2D and LS3D to replace conventional methods must be based on an individual user's criteria.

摘要

通过移动应用程序来确定身体成分可能会规避传统方法的局限性。然而,许多技术的准确性仍然未知。本研究评估了一种移动应用程序(LS)的收敛和同时效度,该应用程序采用二维数字摄影(LS2D)和三维光子扫描(LS3D)。使用 LS 和各种传统方法——Gulick 带、生物电阻抗分析(BIA)和皮褶——从 240 名健康成年人中获得了身体成分的测量值,包括周长、腰臀比(WHR)和体脂百分比(BF%)。收敛效度始终很高,表明这些方法成比例变化,因此尽管存在个体测量差异,但可以可靠地检测到变化。使用 LS 的界限协议(LoA)范围与传统方法之间的 LoA 相当。LS3D 在测量 WHR 时与 Gulick 带具有高度一致性,尽管与个体腰围和臀围的一致性较差。在 BF%方面,LS2D 与 BIA 和皮褶方法具有高度一致性,而 LS3D 则表现出低一致性。有趣的是,根据现有数据推断 LS3D 与 DXA 之间的低偏差表明 LS3D 可能与双能 X 射线吸收法具有高度一致性。总体而言,LS2D 和 LS3D 是否适合替代传统方法必须基于个人用户的标准。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/591d/7663304/f074395fb718/sensors-20-06165-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验