Suppr超能文献

相似文献

1
Update on latest advances in time-of-flight PET.
Phys Med. 2020 Dec;80:251-258. doi: 10.1016/j.ejmp.2020.10.031. Epub 2020 Nov 16.
3
4
High-frequency SiPM readout advances measured coincidence time resolution limits in TOF-PET.
Phys Med Biol. 2019 Feb 27;64(5):055012. doi: 10.1088/1361-6560/aafd52.
5
Scalable electronic readout design for a 100 ps coincidence time resolution TOF-PET system.
Phys Med Biol. 2021 Apr 14;66(8). doi: 10.1088/1361-6560/abf1bc.
6
Crystal surface and reflector optimization for the SiPM-based dual-ended readout TOF-DOI PET detector.
Biomed Phys Eng Express. 2020 Nov 4;6(6). doi: 10.1088/2057-1976/abc45a.
8
On timing-optimized SiPMs for Cherenkov detection to boost low cost time-of-flight PET.
Phys Med Biol. 2023 Aug 9;68(16):165016. doi: 10.1088/1361-6560/ace8ee.
9
A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept.
Phys Med Biol. 2016 Feb 21;61(4):1608-33. doi: 10.1088/0031-9155/61/4/1608. Epub 2016 Feb 2.
10
Performance of long rectangular semi-monolithic scintillator PET detectors.
Med Phys. 2019 Apr;46(4):1608-1619. doi: 10.1002/mp.13432. Epub 2019 Feb 20.

引用本文的文献

1
Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method.
IEEE Trans Instrum Meas. 2025;74. doi: 10.1109/tim.2025.3570343. Epub 2025 May 15.
2
Timing Performance with Broadcom Metal Trench Silicon Photomultipliers.
IEEE Trans Radiat Plasma Med Sci. 2025 Apr;9(4):406-411. doi: 10.1109/trpms.2024.3518479. Epub 2024 Dec 16.
4
FPGA-based digitizer for BGO-based time-of-flight PET.
Phys Med Biol. 2025 Mar 28;70(7). doi: 10.1088/1361-6560/adc362.
5
Flexible and modular PET: Evaluating the potential of TOF-DOI panel detectors.
Med Phys. 2025 May;52(5):2845-2860. doi: 10.1002/mp.17741. Epub 2025 Mar 16.
6
Recent Breakthroughs in PET-CT Multimodality Imaging: Innovations and Clinical Impact.
Bioengineering (Basel). 2024 Nov 30;11(12):1213. doi: 10.3390/bioengineering11121213.
9
Radiation Detectors and Sensors in Medical Imaging.
Sensors (Basel). 2024 Sep 26;24(19):6251. doi: 10.3390/s24196251.
10
Artificial intelligence for response prediction and personalisation in radiation oncology.
Strahlenther Onkol. 2025 Mar;201(3):266-273. doi: 10.1007/s00066-024-02281-z. Epub 2024 Aug 30.

本文引用的文献

1
Evaluation of the PETsys TOFPET2 ASIC in multi-channel coincidence experiments.
EJNMMI Phys. 2021 Mar 24;8(1):30. doi: 10.1186/s40658-021-00370-x.
3
Roadmap toward the 10 ps time-of-flight PET challenge.
Phys Med Biol. 2020 Oct 22;65(21):21RM01. doi: 10.1088/1361-6560/ab9500.
4
Pushing Cherenkov PET with BGO via coincidence time resolution classification and correction.
Phys Med Biol. 2020 Jun 5;65(11):115004. doi: 10.1088/1361-6560/ab87f9.
5
Exploring TOF capabilities of PET detector blocks based on large monolithic crystals and analog SiPMs.
Phys Med. 2020 Feb;70:10-18. doi: 10.1016/j.ejmp.2019.12.004. Epub 2020 Jan 11.
7
PennPET Explorer: Design and Preliminary Performance of a Whole-Body Imager.
J Nucl Med. 2020 Jan;61(1):136-143. doi: 10.2967/jnumed.119.229997. Epub 2019 Jun 21.
9
Dual-ended readout of bismuth germanate to improve timing resolution in time-of-flight PET.
Phys Med Biol. 2019 May 10;64(10):105007. doi: 10.1088/1361-6560/ab18da.
10
Performance Characteristics of the Digital Biograph Vision PET/CT System.
J Nucl Med. 2019 Jul;60(7):1031-1036. doi: 10.2967/jnumed.118.215418. Epub 2019 Jan 10.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验