Schepens Eye Research Institute of Massachusetts Eye and Ear, Boston, Massachusetts, USA
Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts, USA.
Br J Ophthalmol. 2022 Oct;106(10):1450-1456. doi: 10.1136/bjophthalmol-2021-318806. Epub 2021 Apr 22.
Quantification of dark adaptation (DA) response using the conventional rod intercept time (RIT) requires very long testing time and may not be measurable in the presence of impairments due to diseases such as age-related macular degeneration (AMD). The goal of this study was to investigate the advantages of using area under the DA curve (AUDAC) as an alternative to the conventional parameters to quantify DA response.
Data on 136 eyes (AMD: 98, normal controls: 38) from an ongoing longitudinal study on AMD were used. DA was measured using the AdaptDx 20 min protocol. AUDAC was computed from the raw DA characteristic curve at different time points, including 6.5 min and 20 min (default). The presence of AMD in the given eye was predicted using a logistic regression model within the leave-one-out cross-validation framework, with DA response as the predictor while adjusting for age and gender. The DA response variable was either the AUDAC values computed at 6.5 min (AUDAC6.5) or at 20 min (AUDAC20) cut-off, or the conventional RIT.
AUDAC6.5 was strongly correlated with AUDAC20 (β=86, p<0.001, R=0.87). The accuracy of predicting the presence of AMD using AUDAC20 was 76%, compared with 79% when using RIT, the current gold standard. In addition, when limiting AUDAC calculation to 6.5 min cut-off, the predictive accuracy of AUDAC6.5 was 80%.
AUDAC can be a valuable measure to quantify the overall DA response and can potentially facilitate shorter testing duration while maintaining diagnostic accuracy.
使用传统的杆截时(RIT)量化暗适应(DA)反应需要非常长的测试时间,并且在由于年龄相关性黄斑变性(AMD)等疾病导致的损伤存在的情况下可能无法测量。本研究的目的是研究使用暗适应曲线下面积(AUDAC)替代传统参数来量化 DA 反应的优势。
使用正在进行的 AMD 纵向研究中的 136 只眼睛(AMD:98 只,正常对照组:38 只)的数据。使用 AdaptDx 20 分钟方案测量 DA。在不同时间点(包括 6.5 分钟和 20 分钟(默认))从原始 DA 特征曲线上计算 AUDAC。在留一交叉验证框架内,使用逻辑回归模型预测给定眼睛中的 AMD 存在情况,将 DA 反应作为预测因子,同时调整年龄和性别。DA 反应变量是在 6.5 分钟(AUDAC6.5)或 20 分钟(AUDAC20)截止值处计算的 AUDAC 值,或使用传统的 RIT。
AUDAC6.5 与 AUDAC20 高度相关(β=86,p<0.001,R=0.87)。使用 AUDAC20 预测 AMD 存在的准确性为 76%,而使用当前的金标准 RIT 则为 79%。此外,当将 AUDAC 计算限制为 6.5 分钟截止值时,AUDAC6.5 的预测准确性为 80%。
AUDAC 可以是一种量化整体 DA 反应的有价值的指标,并且可以在保持诊断准确性的同时,潜在地缩短测试持续时间。