Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China.
Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China.
Int J Environ Res Public Health. 2021 Jul 30;18(15):8076. doi: 10.3390/ijerph18158076.
This report surveyed the image reject rates of intra-oral, extra-oral, and cone-beam computed tomography (CBCT) imaging in the academic literature. PubMed, Web of Science, and Scopus databases were queried in mid-April 2021. Manual screening of the reference lists of the identified publications was performed to identify papers missed from the database search. All publications returned by the searches were initially included. Exclusion criteria included irrelevance, no reporting of reject rate, no access to the article, and not original article. The total number of images and the number of rejects were recorded for each type of radiographic images. Factors and commonest errors associated with the rejects were recorded. Twenty-six original articles were identified and reviewed. The average reject rate was 11.25% for bitewings, 16.38% for periapicals, 4.10% for panoramics, 6.08% for lateral cephalography, and 2.77% for CBCT. Positioning error and patient movement were two common reasons for the rejects. The average reject rates computed from data pooled across studies should form the reference values for quality assurance programs to follow. Future reject analysis studies should report more radiographic parameters such as type of collimation for intra-oral radiography and patient posture for CBCT.
本报告调查了口腔内、口腔外和锥形束 CT(CBCT)成像在学术文献中的图像拒检率。2021 年 4 月中旬,在 PubMed、Web of Science 和 Scopus 数据库中进行了检索。对已确定出版物的参考文献进行了手动筛选,以确定从数据库搜索中遗漏的论文。搜索返回的所有出版物最初都被包括在内。排除标准包括不相关、未报告拒检率、无法获取文章以及不是原创文章。记录了每种类型射线照相图像的总图像数和拒检数。记录了与拒检相关的因素和最常见的错误。共确定并审查了 26 篇原始文章。磨牙片的平均拒检率为 11.25%,根尖片为 16.38%,全景片为 4.10%,侧位片为 6.08%,CBCT 为 2.77%。定位错误和患者移动是拒检的两个常见原因。从跨研究数据中计算得出的平均拒检率应成为质量保证计划遵循的参考值。未来的拒检分析研究应报告更多射线照相参数,例如口腔内射线照相的准直类型和 CBCT 的患者姿势。