Suppr超能文献

三种根管冲洗剂渗入牙本质小管深度的比较评估

Comparative Evaluation of the Penetration Depth into Dentinal Tubules of Three Endodontic Irrigants.

作者信息

Giardino Luciano, Pedullà Eugenio, Cavani Francesco, Bisciotti Francesca, Giannetti Luca, Checchi Vittorio, Angerame Daniele, Consolo Ugo, Generali Luigi

机构信息

Independent Researcher, 88900 Crotone, Italy.

Department of General Surgery and Surgical-Medical Specialties, University of Catania, 95131 Catania, Italy.

出版信息

Materials (Basel). 2021 Oct 6;14(19):5853. doi: 10.3390/ma14195853.

Abstract

This study aimed to examine the penetration depth into dentinal tubules of some chelating agents. The 17% EDTA and two preparations containing surfactants (Smear Clear, Bioakt Endo) were tested. Surface tension and liquid viscosity were measured using a Dynamic Contact Angle Analyzer and a Haake rotational rheometer. To measure the penetration depth inside dentinal tubules, thirty maxillary central incisors were selected from a pool of extracted human permanent teeth and allocated to three experimental groups (10 samples each), as well as were mechanically shaped and cleansed with 5.25% NaOCl, followed by each of the chelators being labeled with 0.1 wt % Rhodamine B according to final irrigation protocol established. The samples were embedded in an epoxy resin, after which 200 μm thick transverse sections were obtained at 2, 5, and 8 mm from the apex with a saw microtome. The specimens were then observed using a confocal laser microscope (CLSM) and the penetration of the labeled solution was measured in every third of each sample. Statistical analysis was performed using ANOVA or Kruskal-Wallis tests according to the distribution of data, evaluated with the Shapiro-Wilk normality test. Viscosity and surface tension tests have shown that BioAKT Endo has the lowest values compared to EDTA and Smear Clear. The medium penetration depth did not significantly differ among the three irrigants, while it increased considerably from the apical to the coronal level in all groups. Additionally, the maximum penetration depth increased significantly from the apical to coronal level, while among groups, BioAKT Endo showed the highest values at the apical and middle level compared to the other irrigants. No significant differences were observed among the three groups in medium and maximum penetration depths when the entire root was considered. New irrigants containing surfactants show reduced surface tension and, in one case (BioAKT Endo), viscosity. The lowering of the surface tension allows for better penetration of liquids into dentinal tubules than EDTA alone, thus improving the cleaning of the root canal system.

摘要

本研究旨在检测某些螯合剂渗入牙本质小管的深度。测试了17%的乙二胺四乙酸(EDTA)以及两种含有表面活性剂的制剂(Smear Clear、Bioakt Endo)。使用动态接触角分析仪和哈克旋转流变仪测量表面张力和液体粘度。为了测量牙本质小管内的渗透深度,从拔除的人类恒牙中选取30颗上颌中切牙,分配到三个实验组(每组10个样本),进行机械预备并用5.25%的次氯酸钠冲洗,然后根据既定的最终冲洗方案,每种螯合剂用0.1 wt%的罗丹明B标记。将样本嵌入环氧树脂中,之后用锯式切片机在距离根尖2、5和8毫米处获得200μm厚的横向切片。然后使用共聚焦激光显微镜(CLSM)观察标本,并在每个样本的每三分之一处测量标记溶液的渗透情况。根据数据分布,使用方差分析(ANOVA)或克鲁斯卡尔 - 沃利斯检验进行统计分析,并用夏皮罗 - 威尔克正态性检验进行评估。粘度和表面张力测试表明,与EDTA和Smear Clear相比,BioAKT Endo的值最低。三种冲洗剂的平均渗透深度没有显著差异,而在所有组中,从根尖向冠方水平均显著增加。此外,最大渗透深度从根尖向冠方水平显著增加,而在各实验组中,与其他冲洗剂相比,BioAKT Endo在根尖和中部水平显示出最高值。当考虑整个牙根时,三组之间在平均和最大渗透深度方面没有观察到显著差异。含有表面活性剂的新型冲洗剂显示出降低的表面张力,在一种情况下(BioAKT Endo)还降低了粘度。表面张力的降低使液体比单独的EDTA能更好地渗入牙本质小管,从而改善根管系统的清洁。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验