Takakusagi Yosuke, Usui Keisuke, Mizoguchi Nobutaka, Nagatsuka Jun, Hikage Takeshi, Kodama Yasuhiko, Ezura Takatomo, Kusunoki Terufumi, Oizumi Yukio
Department of Radiation Oncology, Kanagawa Cancer Center, Yokohama, JPN.
Department of Radiation Oncology, Juntendo University, Tokyo, JPN.
Cureus. 2021 Sep 16;13(9):e18034. doi: 10.7759/cureus.18034. eCollection 2021 Sep.
Background/Aim The aim of this study was to compare volumetric-modulated arc therapy (VMAT) radiation plans between conventional VMAT with flattening filter (cFF-VMAT) and flattening filter-free VMAT (FFF-VMAT) for localized prostate cancer. Materials and methods Ten patients with localized prostate cancer who underwent cFF-VMAT at Yokosuka General Hospital Uwamachi, Yokosuka, Japan, from July 2020 to October 2020 were enrolled. Dose-volume histogram (DVH) parameters of the target volume, normal organs, monitor units (MU), and beam-on time (BOT) were compared between cFF-VMAT and FFF-VMAT plans. Results No significant difference was observed for DVH parameters for the target volume. No significant difference was observed in all parameters for the bladder and rectum between the cFF-VMAT and FFF-VMAT groups. The mean values of MU were 686 ± 52 and 784 ± 80 in cFF-VMAT and FFF-VMAT, respectively (p < 0.001). The mean BOT was 97.0 ± 6.6 s and 72.9 ± 1.4 s for cFF-VMAT and FFF-VMAT, respectively (p < 0.001). Conclusion DVH parameters of the target volume and normal organs were not significantly different between the cFF-VMAT and FFF-VMAT plans. In FFF-VMAT, MU was significantly higher, and the BOT was significantly shorter than those in cFF-VMAT.
背景/目的 本研究的目的是比较适形调强弧形放疗(VMAT)用于局限性前列腺癌时,传统带均整器的VMAT(cFF-VMAT)和无均整器的VMAT(FFF-VMAT)的放疗计划。材料与方法 纳入2020年7月至2020年10月在日本横须贺宇町横须贺综合医院接受cFF-VMAT治疗的10例局限性前列腺癌患者。比较cFF-VMAT和FFF-VMAT计划中靶区体积、正常器官的剂量体积直方图(DVH)参数、监测单位(MU)和照射时间(BOT)。结果 靶区体积的DVH参数无显著差异。cFF-VMAT组和FFF-VMAT组膀胱和直肠的所有参数均无显著差异。cFF-VMAT和FFF-VMAT的MU平均值分别为686±52和784±80(p<0.001)。cFF-VMAT和FFF-VMAT的平均BOT分别为97.0±6.6秒和72.9±1.4秒(p<0.001)。结论 cFF-VMAT和FFF-VMAT计划中靶区体积和正常器官的DVH参数无显著差异。在FFF-VMAT中,MU显著更高,BOT显著短于cFF-VMAT。