Suppr超能文献

表面肌电双极检测中桡侧腕屈肌的电极大小和放置:范围综述。

Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review.

机构信息

LAM-Motion Analysis Laboratory, S. Sebastiano Hospital, Neuromotor and Rehabilitation Department, Azienda USL-IRCCS di Reggio Emilia, Via Circondaria 29, 42015 Correggio, Italy.

Merlo Bioengineering, 43100 Parma, Italy.

出版信息

Sensors (Basel). 2021 Nov 3;21(21):7322. doi: 10.3390/s21217322.

Abstract

The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and bioengineering applications. The reliability of the sEMG measurement strongly relies on the characteristics of the detection system used, because of possible crosstalk from the surrounding forearm muscles. We conducted a scoping review of the main databases to explore available guidelines of electrode placement on BRD and to map the electrode configurations used and authors' awareness on the issues of crosstalk. One hundred and thirty-four studies were included in the review. The crosstalk was mentioned in 29 studies, although two studies only were specifically designed to assess it. One hundred and six studies (79%) did not even address the issue by generically placing the sensors above BRD, usually choosing large disposable ECG electrodes. The analysis of the literature highlights a general lack of awareness on the issues of crosstalk and the need for adequate training in the sEMG field. Three guidelines were found, whose recommendations have been compared and summarized to promote reliability in further studies. In particular, it is crucial to use miniaturized electrodes placed on a specific area over the muscle, especially when BRD activity is recorded for clinical applications.

摘要

肱桡肌(BRD)是主要的肘屈肌之一,在生理学、临床、运动、工效学和生物工程应用中,常通过表面肌电图(sEMG)进行评估。sEMG 测量的可靠性强烈依赖于所使用的检测系统的特性,因为可能会受到周围前臂肌肉的串扰。我们对主要数据库进行了范围界定审查,以探讨 BRD 电极放置的现有指南,并绘制使用的电极配置图以及作者对串扰问题的认识。该综述纳入了 134 项研究。虽然有两项研究专门设计用于评估,但在 29 项研究中提到了串扰。106 项研究(79%)甚至没有通过笼统地将传感器放置在 BRD 上方来解决该问题,通常选择大尺寸的一次性心电图电极。文献分析突出表明,人们普遍缺乏对串扰问题的认识,并且需要在 sEMG 领域进行充分的培训。发现了三个指南,对其建议进行了比较和总结,以促进进一步研究的可靠性。特别是,当 BRD 活动用于临床应用时,使用放置在肌肉特定区域上的微型化电极至关重要。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0b77/8587451/9c6b1cd03909/sensors-21-07322-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验