Suppr超能文献

比较用于测量唐氏综合征青少年身体活动和久坐时间的加速度计切点。

A comparison of accelerometer cut-points for measuring physical activity and sedentary time in adolescents with Down syndrome.

机构信息

Department of Pediatrics, University of Kansas Medical Center, 3901 Rainbow Boulevard, Kansas City, KS 66160, USA; Center for Children's Healthy Lifestyles & Nutrition, 610 E 22nd Street, Kansas City, MO 64108, USA.

Center for Children's Healthy Lifestyles & Nutrition, 610 E 22nd Street, Kansas City, MO 64108, USA; Children's Mercy Hospital, 610 E 22nd Street, Kansas City, MO 64108, USA.

出版信息

Res Dev Disabil. 2022 Jan;120:104126. doi: 10.1016/j.ridd.2021.104126. Epub 2021 Nov 24.

Abstract

BACKGROUND

No cut-points have been developed for youth with Down syndrome; there is concern that altered gait patterns, decreased energy expenditure and exercise capacity of individuals with Down syndrome may produce inaccurate physical activity data if accelerometer data are analyzed using cut-points from populations with typical development and other IDD diagnoses.

AIM

To compare physical activity and sedentary time across existing accelerometer cut-point methods in adolescents with Down syndrome.

METHODS

In this cross-sectional analysis, participants diagnosed with Down syndrome (n = 37; 15.5 ± 1.9 years; 57 % female) wore an accelerometer on their non-dominant hip for seven-days. Data were analyzed and compared across four physical activity intensity cut-points: Evenson, Freedson 4-MET, McGarty, and Romanizi.

OUTCOMES & RESULTS: Differences in time spent in each intensity across cut-point methods were evident for sedentary (448-615 min/day), light (72-303 min/day) and moderate-to-vigorous (12-77 min/day) activities. Between 0.0-67.6 % of the sample met the physical activity guidelines, depending on the cut-point method selected.

CONCLUSIONS & IMPLICATIONS: This study presents the wide variation of accumulated physical activity minutes when different cut-points are applied to individuals with Down syndrome. There is a critical need to establish Down syndrome-specific measures of physical activity assessment rather than applying methods developed for their peers with typical development.

WHAT THIS PAPER ADDS

This paper highlights concerns over the application of objective measurements of physical activity in youth with Down syndrome from measurement methods derived from populations with typical development. This is the first manuscript to examine this issue in a sample comprised solely of youth with Down syndrome. Results demonstrate the large variation in time spent in each activity intensity that arise due to the application of different cut-point methods.

摘要

背景

目前尚未为唐氏综合征的年轻人制定切点值。人们担心,如果使用典型发育人群和其他智力障碍诊断的切点值分析加速度计数据,唐氏综合征患者的步态模式改变、能量消耗减少和运动能力下降可能会导致不准确的体力活动数据。

目的

比较唐氏综合征青少年使用现有的加速度计切点值方法的体力活动和久坐时间。

方法

在这项横断面分析中,患有唐氏综合征的参与者(n=37;15.5±1.9 岁;57%为女性)在非优势髋部佩戴加速度计,持续 7 天。数据通过四个体力活动强度切点值进行分析和比较:Evenson、Freedson 4-MET、McGarty 和 Romanizi。

结果

在不同的切点值方法下,久坐时间(448-615 分钟/天)、低强度活动时间(72-303 分钟/天)和中高强度活动时间(12-77 分钟/天)的时间分配存在显著差异。根据所选切点值方法,有 0.0-67.6%的样本符合体力活动指南。

结论

本研究表明,当应用不同的切点值时,唐氏综合征患者的累积体力活动分钟数存在很大差异。迫切需要制定针对唐氏综合征患者的体力活动评估的特定方法,而不是应用针对其具有典型发育的同龄人开发的方法。

本文的意义

本文强调了在唐氏综合征青少年中应用源自典型发育人群的测量方法的体力活动客观测量方法的应用存在问题。这是第一篇仅在唐氏综合征青少年样本中研究此问题的论文。结果表明,由于应用不同的切点值方法,不同活动强度的时间分配存在很大差异。

相似文献

本文引用的文献

7
Step-counting accuracy of activity monitors in persons with Down syndrome.计步器在唐氏综合征患者中的计步准确性。
J Intellect Disabil Res. 2019 Jan;63(1):21-30. doi: 10.1111/jir.12550. Epub 2018 Sep 21.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验