基于超声评估的桡动脉远端参考直径及特征。

Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment.

机构信息

Division of Cardiology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, Wonju, Korea.

Department of Biostatistics, Yonsei University Wonju College of Medicine, Wonju, Korea.

出版信息

Korean J Intern Med. 2022 Jan;37(1):109-118. doi: 10.3904/kjim.2020.685. Epub 2021 Dec 29.

Abstract

BACKGROUND/AIMS: While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to determine the DRA reference diameters of Korean patients and identify the predictors of DRA diameter < 2.3 mm.

METHODS

The outer bilateral DRA diameters were assessed using a linear ultrasound probe in 1,162 consecutive patients who underwent transthoracic echocardiography. The DRA diameter was measured by the perpendicular angle in the dorsum of the hand, and the average values were compared by sex. DRA diameter < 2.3 mm was defined as unsuitable for routine diagnostic coronary angiography using a 5 Fr introducer sheath.

RESULTS

The mean DRA diameters were 2.31 ± 0.43 mm (right) and 2.35 ± 0.45 mm (left). The DRA was smaller in women than men (right: 2.15 ± 0.38 mm vs. 2.43 ± 0.44 mm, p < 0.001; left: 2.18 ± 0.39 mm vs. 2.47 ± 0.45 mm, p < 0.001). The DRA diameter was approximately 20% smaller than the radial artery diameter. A total of 630 (54.2%) and 574 (49.4%) patients had DRA diameter < 2.3 mm in the right and left hands, respectively. Female sex, low body mass index (BMI), and low body surface area (BSA) were significant predictors of DRA diameter < 2.3 mm.

CONCLUSION

We provided reference DRA diameters for Korean patients. Approximately 50% of the studied patients had DRA diameter < 2.3 mm. Female sex, low BMI, and low BSA remained significant predictors of DRA diameter < 2.3 mm.

摘要

背景/目的:虽然远端桡动脉(DRA)通路越来越多地用于诊断性冠状动脉造影,但关于 DRA 大小的信息有限。我们旨在确定韩国患者的 DRA 参考直径,并确定 DRA 直径<2.3mm 的预测因素。

方法

在 1162 例连续接受经胸超声心动图检查的患者中,使用线性超声探头评估双侧 DRA 外径。DRA 直径在手背的垂直角度进行测量,平均值按性别进行比较。DRA 直径<2.3mm 定义为不适合使用 5Fr 导入鞘进行常规诊断性冠状动脉造影。

结果

平均 DRA 直径分别为右侧 2.31±0.43mm 和左侧 2.35±0.45mm。女性的 DRA 直径小于男性(右侧:2.15±0.38mm 比 2.43±0.44mm,p<0.001;左侧:2.18±0.39mm 比 2.47±0.45mm,p<0.001)。DRA 直径比桡动脉直径小约 20%。右手和左手 DRA 直径<2.3mm 的患者分别有 630(54.2%)和 574(49.4%)例。女性、低体重指数(BMI)和低体表面积(BSA)是 DRA 直径<2.3mm 的显著预测因素。

结论

我们为韩国患者提供了 DRA 直径的参考值。大约 50%的研究患者的 DRA 直径<2.3mm。女性、低 BMI 和低 BSA 仍然是 DRA 直径<2.3mm 的显著预测因素。