Poulain D, Fruit J, Fournier L, Dei Cas E, Vernes A
Eur J Clin Microbiol. 1986 Aug;5(4):427-34. doi: 10.1007/BF02075699.
The accuracy of co-counterimmunoelectrophoresis was compared with mycological and clinical data for different groups of inpatients. The specificity and sensitivity of this method ranged from 100 to 69%. The co-specific precipitin line was observed during systemic infections caused by most opportunistic Candida species. The variations in the line in successive serum samples provided a simple means of serological surveillance. The test also detected seroconversion. The gradual disappearance of the line reflected a favourable prognosis, whereas its abrupt disappearance indicated unfavourable prognosis and correlated with the appearance of detectable circulating antigens.
将协同对流免疫电泳的准确性与不同住院患者组的真菌学和临床数据进行了比较。该方法的特异性和敏感性范围为100%至69%。在大多数机会性念珠菌属引起的全身感染期间观察到共同特异性沉淀线。连续血清样本中该沉淀线的变化提供了一种简单的血清学监测方法。该试验还检测到血清转化。沉淀线的逐渐消失反映预后良好,而其突然消失则表明预后不良,并与可检测到的循环抗原的出现相关。