Suppr超能文献

通过串联巨磁阻分析法对不同丰度的多种生物标志物进行一次性全范围定量

One-Shot Full-Range Quantification of Multi-Biomarkers With Different Abundance by a Tandem Giant Magnetoresistance Assay.

作者信息

Meng Fanda, Zhang Lei, Lian Jie, Huo Weisong, Shi Xizeng, Gao Yunhua

机构信息

Department of Clinical Laboratory Medicine, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Medicine and Health Key Laboratory of Laboratory Medicine, Jinan, China.

School of Clinical and Basic Medicine, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, China.

出版信息

Front Chem. 2022 May 19;10:911795. doi: 10.3389/fchem.2022.911795. eCollection 2022.

Abstract

In this study, we reported a tandem giant magnetoresistance (GMR) assay that realized the one-shot quantification of multi-biomarkers of infection, C-reactive protein (CRP) with procalcitonin (PCT), and neutrophil gelatinase-associated lipocalin (NGAL), all of which could cover their clinically relevant concentration ranges under a different principle. In the presence of co-determined assay, we quantified these three biomarkers in undiluted human blood serum in a single test. The tandem principle, based on which quantification of CRP occurs, combines a sandwich assay and an indirect competitive assay, which allows for the discrimination of the concentration values resulting from the multivalued dose-response curve ('Hook' effect), which characterizes the one-step sandwich assay at high CRP concentrations. However, the entire diagnostically dynamic range, in the quantification of PCT and NGAL, was achieved by differential coating of two identical GMR sensors operated in tandem and by combining two standard curves. The sensor quantified low detection limits and a broader dynamic range for the detection of infection biomarkers. The noticeable features of the assay are its dynamic range and small sample volume requirement (50 μL), and the need for a short measurement time of 15 min. These figures of merit render it a prospective candidate for practical use in point-of-care analysis.

摘要

在本研究中,我们报道了一种串联巨磁电阻(GMR)检测方法,该方法实现了对感染的多种生物标志物(即与降钙素原(PCT)和中性粒细胞明胶酶相关脂质运载蛋白(NGAL)一起的C反应蛋白(CRP))的一次性定量,所有这些生物标志物均可在不同原理下覆盖其临床相关浓度范围。在联合测定分析中,我们在一次检测中对未稀释的人血清中的这三种生物标志物进行了定量。基于该原理对CRP进行定量,结合了夹心分析和间接竞争分析,这使得能够区分由多值剂量反应曲线(“钩状”效应)产生的浓度值,该效应在高CRP浓度下表征一步夹心分析。然而,在PCT和NGAL的定量中,整个诊断动态范围是通过串联操作的两个相同GMR传感器的差异涂层以及结合两条标准曲线来实现的。该传感器对感染生物标志物的检测具有低检测限和更宽的动态范围。该检测方法的显著特点是其动态范围、小样本体积要求(50μL)以及仅需15分钟的短测量时间。这些优点使其成为即时护理分析实际应用的潜在候选方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6e20/9185946/53550141e797/fchem-10-911795-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验