Abstract

Virtual reality (VR) systems are becoming increasingly attractive as joint kinematics monitoring systems during rehabilitation. This study aimed to evaluate the accuracy of the Oculus Quest 2 in measuring translational and rotational displacements. As the Oculus Quest 2 was chosen for future applications in shoulder rehabilitation, the translation range (minimum: ~200 mm, maximum: ~700 mm) corresponded to the forearm length of the 5th percentile female and the upper limb length of the 95th percentile male. The controller was moved on two structures designed to allow different translational displacements and rotations in the range 0-180°, to cover the range of motion of the upper limb. The controller measures were compared with those of a Qualisys optical capture system. The results showed a mean absolute error of 13.52 ± 6.57 mm at a distance of 500 mm from the head-mounted display along the x-direction. The maximum mean absolute error for rotational displacements was found to be 1.11 ± 0.37° for a rotation of 40° around the z-axis. Oculus Quest 2 is a promising VR tool for monitoring shoulder kinematics during rehabilitation. The inside-out movement tracking makes Oculus Quest 2 a viable alternative to traditional motion analysis systems.

摘要

虚拟现实(VR)系统作为康复过程中的关节运动学监测系统,正变得越来越有吸引力。本研究旨在评估 Oculus Quest 2 在测量平移和旋转位移方面的准确性。由于 Oculus Quest 2 被选为未来肩部康复的应用设备,其平移范围(最小:200mm,最大:700mm)对应于第 5 百分位女性的前臂长度和第 95 百分位男性的上肢长度。控制器在两个结构上移动,这些结构设计用于允许在 0-180°范围内产生不同的平移和旋转,以覆盖上肢的运动范围。将控制器的测量值与 Qualisys 光学捕捉系统的测量值进行比较。结果表明,在距离头戴式显示器 500mm 的 x 方向上,平均绝对误差为 13.52±6.57mm。在 z 轴上旋转 40°时,旋转位移的最大平均绝对误差为 1.11±0.37°。Oculus Quest 2 是一种有前途的 VR 工具,可用于监测康复过程中的肩部运动学。内部运动跟踪使 Oculus Quest 2 成为传统运动分析系统的可行替代方案。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/54ba/9332705/8a030b59c0ce/sensors-22-05511-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验