Department of Oculoplasty and Ocular Oncology, PBMA's H.V.Desai Eye Hospital, Pune, Maharashtra, India.
Department of General Ophthalmology, PBMA's H.V.Desai Eye Hospital, Pune, Maharashtra, India.
Indian J Ophthalmol. 2022 Aug;70(8):2862-2865. doi: 10.4103/ijo.IJO_19_22.
Phacoemulsification with intraocular lens (IOL) implantation is the standard of care for cataractous eyes. Monofocal IOLs are spherical or aspheric. The aspheric design of IOLs reduces the spherical and higher-order aberrations and impacts contrast sensitivity post cataract surgery. There are some studies, but data in the Indian setting with the IOLs we used is lacking. We aimed to compare the effect of implantation of spheric and aspheric foldable intraocular lenses on postoperative quality of vision, spherical aberration, and contrast sensitivity.
This prospective observational study was conducted at a tertiary care hospital with an ophthalmology specialty, data collection from January 2017 to May 2018 in 100 patients. Patients meeting the inclusion criteria were selected. Their preoperative and postoperative data were collected and divided into groups based on whether spherical or aspheric IOL was implanted after cataract surgery. Variables assessed were visual acuity on days 7 and 30, spherical aberrations, and contrast sensitivity was assessed at 1-month postoperative.
The mean age of the patients in this study was 64 ± 8 years with a majority of patients (60%) being females. There is no significant difference in postoperative visual acuity between the two groups. Internal SA was significantly lower (~50%) in eyes implanted with aspheric IOLs (P value = 0.004, 0.0001) compared with the spherical group. Contrast sensitivity of patients of the aspheric group was significantly better (P value <0.05).
The optical design of the aspheric IOLs reduced spherical aberrations and increased contrast sensitivity.
超声乳化白内障吸除术联合人工晶状体(IOL)植入术是白内障眼的标准治疗方法。单焦点 IOL 有球面或非球面设计。IOL 的非球面设计可减少球差和高阶像差,并影响白内障手术后的对比敏感度。虽然已有一些相关研究,但缺乏我们所使用的 IOL 在印度环境下的数据。本研究旨在比较球面和非球面折叠式人工晶状体植入术后对视觉质量、球差和对比敏感度的影响。
这是一项在一家拥有眼科专科的三级保健医院进行的前瞻性观察性研究,数据收集时间为 2017 年 1 月至 2018 年 5 月,共纳入 100 例患者。入选符合纳入标准的患者,收集其术前和术后数据,并根据白内障手术后植入的 IOL 是球面还是非球面将其分为两组。评估的变量包括术后第 7 天和第 30 天的视力、球差和术后 1 个月的对比敏感度。
本研究患者的平均年龄为 64 ± 8 岁,其中大多数(60%)为女性。两组患者术后视力无显著差异。与球面组相比,植入非球面 IOL 的眼内 SA 明显降低(~50%,P 值=0.004,0.0001)。非球面组患者的对比敏感度明显更好(P 值<0.05)。
非球面 IOL 的光学设计减少了球差,提高了对比敏感度。