Suppr超能文献

基于用于OT桥系统的修复螺钉数量对含四颗种植体的下颌骨模型中负荷分布的评估:有限元分析(FEA)

Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA).

作者信息

Grande Francesco, Pozzan Mario Cesare, Marconato Raul, Mollica Francesco, Catapano Santo

机构信息

Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy.

Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Via Nizza, 230, 10126 Torino, Italy.

出版信息

Materials (Basel). 2022 Nov 10;15(22):7963. doi: 10.3390/ma15227963.

Abstract

In full-arch implant rehabilitations, when the anterior screw abutment channel compromises the aesthetic of the patient, the OT-Bridge system used with its Seeger rings may provide the necessary retention of the prosthesis. However, no studies have evaluated the forces generated at the Seeger level during loading. This Finite Element Analysis aims to investigate the mechanical behavior of Seeger rings in a mandibular model with four implants and an OT-Bridge system, used without one or two anterior prosthetic screws. A 400 N unilateral load was virtually applied on a 7 mm distal cantilever. Two different variables were considered: the constraint conditions using two or three screws instead of four and the three different framework materials (fiberglass reinforced resin, cobalt-chrome, TiAl6V4). The FEA analysis exhibited tensile and compressive forces on the Seeger closest to the loading point. With the resin framework, a tension force on abutment 3.3 generates a displacement from 5 to 10 times greater than that respectively expressed in metal framework materials. In a full-arch rehabilitation with four implants, the case with three prosthetic screws seems to be a safer and more predictable configuration instead of two. Considering the stress value exhibited and the mechanical properties of the Seeger, the presence of only two prosthetic screws could lead to permanent deformation of the Seeger in the screwless abutment closest to the loading point.

摘要

在全牙弓种植修复中,当前方螺钉基台通道影响患者美观时,搭配西格环使用的OT桥系统可提供义齿所需的固位力。然而,尚无研究评估加载过程中西格环处产生的力。本有限元分析旨在研究西格环在具有四颗种植体和OT桥系统的下颌模型中的力学行为,该模型未使用一颗或两颗前方修复螺钉。在一个7毫米远中悬臂上虚拟施加400牛的单侧载荷。考虑了两个不同变量:使用两颗或三颗螺钉而非四颗螺钉的约束条件,以及三种不同的支架材料(玻璃纤维增强树脂、钴铬合金、TiAl6V4)。有限元分析显示,在最靠近加载点的西格环上存在拉力和压力。使用树脂支架时,基台3.3上的拉力产生的位移分别比金属支架材料中的位移大5至10倍。在使用四颗种植体的全牙弓修复中,使用三颗修复螺钉的情况似乎比两颗螺钉的情况更安全、更可预测。考虑到所显示的应力值和西格环的力学性能,仅使用两颗修复螺钉可能会导致最靠近加载点的无螺钉基台中西格环发生永久变形。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7e2e/9699052/6f20b10f5798/materials-15-07963-g001.jpg