Rosenthal S L, Freundlich L F, Washington W
Am J Clin Pathol. 1978 Dec;70(6):914-7. doi: 10.1093/ajcp/70.6.914.
Seventy-two oxidase-positive or nonfermentative organisms, or both, all of which could be identified with reasonable certainty by alternative means, were used to challenge the OXI/FERM tube. There was 91% concurrence of identification between the two methods. Three observers, working independently, agreed upon the interpretation of each of the tests in the OXI/FERM system from 91% to 100% of the time. Duplicate OXI/FERM tubes inoculated with the same strain yielded identical interpretations 95% of the time for all tests except citrate utilization (89%). The OXI/FERM tube thus appeared to be an accurate identification method and yielded test results that were easily interpreted and adequately reproducible.
72株氧化酶阳性或非发酵菌,或两者皆有的菌株,所有这些菌株都能通过其他方法得到合理确定的鉴定结果,用它们对OXI/FERM管进行测试。两种方法的鉴定结果一致性为91%。三位独立工作的观察者,在91%至100%的时间里对OXI/FERM系统中每项测试的结果解释达成一致。接种相同菌株的双份OXI/FERM管,除柠檬酸盐利用试验外(89%),所有测试在95%的时间里产生相同的结果解释。因此,OXI/FERM管似乎是一种准确的鉴定方法,其测试结果易于解释且具有足够的可重复性。