Suppr超能文献

听诊器和健康应用程序系统定量测量健康成年人呼吸频率的可重复性、再现性和同时效度:重复性和有效性研究。

Repeatability, Reproducibility, and Concurrent Validity of a Stethoscope and Health App System for the Quantification of Breath Rate in Healthy Adults: Repeatability and Validity Study.

机构信息

Departamento de Enfermería, Facultad de Enfermería, Fisioterapia y Podología, Universidad Complutense de Madrid, Madrid, Spain.

Departamento de Enfermería y Estomatología, Facultad de CC de la Salud, Universidad Rey Juan Carlos, Alcorcón, Spain.

出版信息

J Med Internet Res. 2023 Jan 12;25:e41845. doi: 10.2196/41845.

Abstract

BACKGROUND

Apps for smartphones that can measure the breathing rate easily can be downloaded.

OBJECTIVE

The aim of this study was to demonstrate agreement in measuring breath rates between the stethoscope and Breath Counter health app.

METHODS

We performed a repeatability study with 56 healthy volunteers. The patient's demographic data and breathing rates per minute were collected. Breathing rates were measured via two methods: (1) using a stethoscope placed in the upper area of the right lung and (2) a Breath Counter app developed by Vadion on a Samsung Fold smartphone.

RESULTS

This study demonstrated high repeatability and validity with respect to the breathing rate parameter of healthy adults using the aforementioned 2 systems. Intrasession repeatability measure using the intraclass correlation coefficient was >0.962, indicating excellent repeatability. Moreover, the intraclass correlation coefficient between methods was 0.793, indicating good repeatability, and coefficients of variation of method errors values were 1.83% with very low values in terms of other repeatability parameters. We found significant correlation coefficients and no systematic differences between the app and stethoscope methods.

CONCLUSIONS

The app method may be attractive to individuals who require repeatability in a recreational setting.

摘要

背景

可以下载到能够轻松测量呼吸频率的智能手机应用程序。

目的

本研究旨在展示听诊器和 Breath Counter 健康应用程序在测量呼吸频率方面的一致性。

方法

我们对 56 名健康志愿者进行了可重复性研究。收集了患者的人口统计学数据和每分钟呼吸次数。通过两种方法测量呼吸频率:(1)使用听诊器置于右肺上部,(2)使用由 Vadion 开发的三星 Galaxy Fold 智能手机上的 Breath Counter 应用程序。

结果

本研究使用上述两种系统对健康成年人的呼吸率参数显示出高度的可重复性和有效性。使用组内相关系数(intraclass correlation coefficient)评估的日内重复性测量值>0.962,表明具有极好的重复性。此外,两种方法之间的组内相关系数为 0.793,表明具有良好的重复性,方法误差值的变异系数为 1.83%,其他重复性参数的数值非常低。我们发现应用程序方法和听诊器方法之间具有显著的相关系数且无系统差异。

结论

对于需要在娱乐环境中具有可重复性的个体来说,应用程序方法可能具有吸引力。