Suppr超能文献

老年人群屈光不正与眼生物测量之间的关联

Association between Refractive Errors and Ocular Biometry in an Elderly Population.

作者信息

Hashemi Hassan, Bouyeh Aria, Khabazkhoob Mehdi

机构信息

Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran.

Department of Basic Sciences, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

出版信息

Optom Vis Sci. 2023 Jan 1;100(1):74-81. doi: 10.1097/OPX.0000000000001966. Epub 2022 Dec 3.

Abstract

SIGNIFICANCE

The anterior chamber depth in hyperopic eyes is significantly deeper than that in myopic eyes, and this finding is independent of the axial length.

PURPOSE

This study aimed to determine the relationship between and refractive errors and ocular biometric components in a geriatric population 60 years and older.

METHODS

The present population-based cross-sectional study was performed using a multistage random cluster sampling method in Tehran, Iran. After selecting the samples, visual acuity measurement, autorefraction, subjective refraction, and slit-lamp examination were performed for all participants. Ocular biometric indices were measured with Pentacam AXL (Oculus, Wetzlar, Germany).

RESULTS

The correlation coefficients of spherical equivalent with axial length, corneal radius of curvature, axial length/corneal radius of curvature ratio, and anterior chamber depth were -0.40, 0.14, -0.63, and -0.18, respectively, after controlling the effects of age, sex, and nuclear cataract. The axial length (24.84 vs. 21.21 mm), the anterior chamber depth (2.74 vs. 2.34 mm), the ratio of the axial length to the corneal radius of curvature (3.35 vs. 2.71), and the anterior chamber volume (138.59 and 105.54 mm 3 ) were the highest and lowest in myopic and hyperopic individuals, respectively (all P < .001). In the first model, axial length and nuclear cataract were significantly inversely related to the spherical equivalent. However, corneal radius of curvature, anterior chamber depth, central corneal thickness, and corneal diameter had a significant direct relationship with the spherical equivalent. In the second model, the axial length/corneal radius of curvature ratio and cataract showed an inverse relationship with the spherical equivalent, whereas anterior chamber depth and corneal diameter had a direct relationship with the spherical equivalent.

CONCLUSIONS

Among the biometric components, the axial length/corneal radius of curvature ratio has the strongest relationship with refractive errors. The anterior chamber depth is lower in myopes compared with hyperopes after controlling the effect of axial length.

摘要

意义

远视眼的前房深度明显比近视眼深,且这一发现与眼轴长度无关。

目的

本研究旨在确定60岁及以上老年人群中屈光不正与眼部生物测量成分之间的关系。

方法

本基于人群的横断面研究采用多阶段随机整群抽样方法在伊朗德黑兰进行。选取样本后,对所有参与者进行视力测量、自动验光、主观验光和裂隙灯检查。使用Pentacam AXL(德国韦茨拉尔奥culus公司)测量眼部生物测量指标。

结果

在控制年龄、性别和核性白内障的影响后,等效球镜度与眼轴长度、角膜曲率半径、眼轴长度/角膜曲率半径比和前房深度的相关系数分别为-0.40、0.14、-0.63和-0.18。眼轴长度(24.84对21.21mm)、前房深度(2.74对2.34mm)、眼轴长度与角膜曲率半径之比(3.35对2.71)以及前房容积(138.59和105.54mm³)在近视和远视个体中分别最高和最低(均P<.001)。在第一个模型中,眼轴长度和核性白内障与等效球镜度显著负相关。然而,角膜曲率半径、前房深度、中央角膜厚度和角膜直径与等效球镜度呈显著正相关。在第二个模型中,眼轴长度/角膜曲率半径比和白内障与等效球镜度呈负相关,而前房深度和角膜直径与等效球镜度呈正相关。

结论

在生物测量成分中,眼轴长度/角膜曲率半径比与屈光不正的关系最为密切。在控制眼轴长度的影响后,近视眼的前房深度低于远视眼。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验