Surface roughness changes of two composite resin restorative materials after thermocycling.

作者信息

Imtiaz Taanya, Ganesh S Balaji, Jayalakshmi S

机构信息

Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.

White Lab - Materials Research Center, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.

出版信息

J Adv Pharm Technol Res. 2022 Dec;13(Suppl 2):S466-S469. doi: 10.4103/japtr.japtr_255_22. Epub 2022 Dec 30.

Abstract

Composite is usually a mixture of two phases. The composites used in dentistry have high durability. The individual properties of each phase are important to increase the mechanical property of the composite. This study aimed to determine the surface roughness changes of two composite resin restorative materials after thermocycling. Two of the commercially available composites were chosen (RestoFill and SwissTEC). The composite disks of dimension 10 mm diameter and 3 mm height were prepared using silicone molds, and every increment was light cured for 30 s. A stylus profilometer was used to assess the surface roughness prethermocycling, and then, the disks were subjected to an integrated thermocycler (T.S-4.4) for 1000 cycles. The postsurface roughness was obtained after the thermocycling process using the same stylus profilometer. The surface parameter values before and after thermocycling of the SwissTEC sample is less than that of RestoFill. There was a significant difference between the Rz and Rq values of the two different commercially available composite materials. Thus, the present study concludes that thermocycling influenced the surface roughness of composite resin and increased the surface roughness of both the RestoFill and SwissTEC composites.

摘要

复合材料通常是两相的混合物。牙科中使用的复合材料具有高耐久性。各相的单独性能对于提高复合材料的机械性能很重要。本研究旨在确定两种复合树脂修复材料在热循环后的表面粗糙度变化。选择了两种市售复合材料(RestoFill和SwissTEC)。使用硅树脂模具制备直径10毫米、高3毫米的复合盘,每次增量光固化30秒。使用触针式轮廓仪评估热循环前的表面粗糙度,然后将盘置于综合热循环仪(T.S-4.4)中进行1000次循环。热循环过程后使用相同的触针式轮廓仪获得循环后的表面粗糙度。SwissTEC样品热循环前后的表面参数值小于RestoFill。两种不同市售复合材料的Rz和Rq值之间存在显著差异。因此,本研究得出结论,热循环影响复合树脂的表面粗糙度,并增加了RestoFill和SwissTEC复合材料的表面粗糙度。