Suppr超能文献

根据种植部位和时间评估老年患者种植体稳定性:一项前瞻性多中心队列研究

Evaluation of Implant Stability According to Implant Placement Site and Duration in Elderly Patients: A Prospective Multi-Center Cohort Study.

作者信息

Shim Ji-Suk, Kim Moon-Young, An Se-Jun, Kang Eun-Sung, Choi Yu-Sung

机构信息

Department of Dentistry, Korea University Guro Hospital, Seoul 08308, Republic of Korea.

Department of Oral and Maxillofacial Surgery, College of Dentistry, Dankook University, Cheonan 31116, Republic of Korea.

出版信息

J Clin Med. 2023 Aug 2;12(15):5087. doi: 10.3390/jcm12155087.

Abstract

The aim of this prospective study is to investigate implant stability and the reliability of different measuring devices according to implant placement site and duration in patients aged over 65 years. The study evaluated 60 implants (diameter: 3.5/4.0/4.5/5.0 mm and length: 8.5/10.0/11.5 mm) in 60 patients aged ≥ 65 years. The implant placement sites were divided into six evenly distributed sections ( = 10), i.e., maxillary right-posterior, A; maxillary anterior, B; maxillary left-posterior, C; mandibular right-posterior, D; mandibular anterior, E; mandibular left-posterior, F. Participants visited the hospital six times: implant surgery, 1V; stitch removal, 2V; 1-month follow-up, 3V; 2-month follow-up, 4V; before final restoration delivery, 5V; and after final restoration delivery, 6V. The implant stability was evaluated with the Osstell Mentor (ISQ), Periotest M (PTV), and Anycheck (IST). The mean values of ISQ, PTV, and IST were analyzed (α = 0.05). ISQ, PTV, and IST results of 4V and 5V were significantly higher than those of 1V ( < 0.05). The lowest ISQ results occurred in the E location at 4V and 5V ( < 0.05). In all mandibular locations, IST results of 6V were significantly higher than those of 1V, 2V, 3V, and 4V ( < 0.05). ISQ results were negatively correlated with PTV and positively correlated with IST, and PTV was negatively correlated with IST. By considering various factors affecting the stability of the implant, it is necessary to determine the appropriate implant load application time. This could help increase the implant success rate in elderly patients. And as a diagnostic device for implant stability and the evaluation of osseointegration in elderly patients, Anycheck was also able to prove its relative reliability compared to Osstell ISQ Mentor and Periotest M.

摘要

这项前瞻性研究的目的是调查65岁以上患者中,根据种植体植入部位和时间,种植体稳定性以及不同测量设备的可靠性。该研究评估了60例年龄≥65岁患者的60颗种植体(直径:3.5/4.0/4.5/5.0毫米;长度:8.5/10.0/11.5毫米)。种植体植入部位分为六个均匀分布的区域( = 10),即上颌右后牙区,A;上颌前牙区,B;上颌左后牙区,C;下颌右后牙区,D;下颌前牙区,E;下颌左后牙区,F。参与者共到医院就诊六次:种植手术,第1次就诊;拆线,第2次就诊;1个月随访,第3次就诊;2个月随访,第4次就诊;最终修复体交付前,第5次就诊;最终修复体交付后,第6次就诊。使用Osstell Mentor(ISQ)、Periotest M(PTV)和Anycheck(IST)评估种植体稳定性。分析ISQ、PTV和IST的平均值(α = 0.05)。第4次和第5次就诊时的ISQ、PTV和IST结果显著高于第1次就诊时的结果( < 0.05)。第4次和第5次就诊时,E区域的ISQ结果最低( < 0.05)。在所有下颌区域,第6次就诊时的IST结果显著高于第1次、第2次、第3次和第4次就诊时的结果( < 0.05)。ISQ结果与PTV呈负相关,与IST呈正相关,且PTV与IST呈负相关。考虑到影响种植体稳定性的各种因素,有必要确定合适的种植体加载应用时间。这有助于提高老年患者的种植成功率。并且作为一种用于评估老年患者种植体稳定性和骨整合的诊断设备,与Osstell ISQ Mentor和Periotest M相比,Anycheck也能够证明其相对可靠性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9f7a/10419881/9b13d1c1db5e/jcm-12-05087-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验