Suppr超能文献

验证慢性耳部调查的德语版本,并与一个既定的德语测量工具进行心理测量比较。

Validation of the German language version of the Chronic Ear Survey and its psychometric comparison with an established German measurement instrument.

机构信息

Klinik für Hals‑, Nasen‑, Ohrenheilkunde, Charité-Universitätsmedizin Berlin, Campus Virchow-Klinikum, Campus Charite Mitte, Augustenburger Platz 1, 13353, Berlin, Germany.

Universitätsklinikum Carl Gustav Carus Dresden, Dresden, Germany.

出版信息

HNO. 2024 Jan;72(Suppl 1):33-42. doi: 10.1007/s00106-023-01335-5. Epub 2023 Oct 4.

Abstract

BACKGROUND

With the Chronic Ear Survey (CES), a validated measurement instrument for the assessment of disease-specific health-related quality of life (HRQoL) has been available internationally since 2000. The aim of this study was to provide a validated German version of this international instrument and to compare it with the German Chronic Otitis Media Outcome Test 15 (COMOT-15).

METHODOLOGY

The CES was translated into German via a forward-backward translation process. For validation, 79 patients with COM undergoing middle ear surgery were prospectively included. HRQoL was determined preoperatively and 6 months postoperatively using the CES and the COMOT-15. Pure tone audiometry was also performed at both measurement time points. In the control examination, an additional retrospective assessment of the preoperative situation was additionally performed using the CES and the COMOT-15 to assess the response shift. The determined psychometric characteristics were internal consistency, test-retest reliability, discrimination validity, agreement validity, responsiveness, and response shift for both measurement instruments. Convergent validity of both measurement instruments was assessed using linear regression.

RESULTS

On the basis of the CES, patients with COM could be reliably distinguished from patients with healthy ears. The CES showed satisfactory reliability with high internal consistency (Cronbach α 0.65-0.85) and high retest reliability (r > 0.8). The global assessment of HRQoL impairment correlated very well with the scores of the CES (r = 0.51). In addition, it showed a high sensitivity to change (standardized response mean -0.86). Compared to the COMOT-15, it showed a lower response shift (effect size -0.17 vs. 0.44). Both measurement instruments correlated only slightly with air conduction hearing threshold (r = 0.29 and r = 0.24, respectively). The concordant validity of both measurement instruments was high (r = 0.68).

CONCLUSION

The German version of the CES shows satisfactory psychometric characteristics, so that its use can be recommended. The CES focuses on the influence of ear symptoms on HRQoL, whereas the COMOT-15 also includes functional and psychological aspects. Due to only minor response shift effects, the CES is particularly suitable for studies with multiple repeat measurements.

摘要

背景

自 2000 年以来,慢性耳部调查(CES)作为一种评估特定疾病健康相关生活质量(HRQoL)的有效测量工具,在国际上得到了应用。本研究的目的是提供该国际工具的经过验证的德文版本,并将其与德国慢性中耳炎结局测试 15 版(COMOT-15)进行比较。

方法

通过正向和反向翻译过程将 CES 翻译成德文。为了验证,前瞻性地纳入了 79 例接受中耳手术的 COM 患者。使用 CES 和 COMOT-15 在术前和术后 6 个月评估 HRQoL。在两个测量时间点也进行了纯音听阈测试。在对照检查中,还使用 CES 和 COMOT-15 对术前情况进行额外的回顾性评估,以评估反应转移。确定了两种测量工具的心理测量特性,包括内部一致性、测试-重测可靠性、区分效度、效标效度、反应性和反应转移。使用线性回归评估两种测量工具的收敛效度。

结果

基于 CES,患有 COM 的患者可以与健康耳朵的患者可靠地区分。CES 表现出令人满意的可靠性,具有较高的内部一致性(Cronbach α 0.65-0.85)和较高的重测可靠性(r>0.8)。HRQoL 损害的总体评估与 CES 的评分非常吻合(r=0.51)。此外,它显示出较高的变化敏感性(标准化反应均值-0.86)。与 COMOT-15 相比,它显示出较低的反应转移(效应大小-0.17 与 0.44)。两种测量工具与气导听阈的相关性均较低(r=0.29 和 r=0.24)。两种测量工具的一致性效度均较高(r=0.68)。

结论

CES 的德文版本具有令人满意的心理测量特性,因此可以推荐使用。CES 侧重于耳部症状对 HRQoL 的影响,而 COMOT-15 还包括功能和心理方面。由于反应转移的影响较小,CES 特别适合于具有多次重复测量的研究。