Department of Dental Surgery, The University of Hong Kong-Shenzhen Hospital, Shenzhen, 518000, China.
Stomatology Student, School of Basic Medical Sciences, Hebei University, Hebei, 050000, China.
BMC Pediatr. 2023 Nov 28;23(1):602. doi: 10.1186/s12887-023-04404-4.
The objective of this study was to evaluate intraobserver reliability and inter-observer reproducibility of a 3-dimensional (3D) assessment method for mandibular changes of growing patients after orthodontic treatment for Class III malocclusion.Methods Cone-beam computed tomography (CBCT) scans were performed before and after orthodontic treatment for 27 patients. During the scan, the patient was positioned such that his/her mandibular plane was parallel to floor. Three observers independently worked on the DICOM data, reconstructed the pre- and post-treatment 3D models in software, selected the stable anatomical structures (basal bone area from the lingual surface of the symphysis to the distal aspect of the first molars) to guide the automated superimposition process. Then, each observer registered 14 anatomical landmarks on the virtual models, for three times after suitable interval, to generate 3 sets of coordinates; the mean was taken as the coordinates for that particular landmark. The intraobserver reliability and inter-observer reproducibility of the method were analyzed.Results The ICCs was > 0.90 for 25 (92.6%) of the intraobserver assessments. The precision of the measurement method was < 0.3 mm in 24 (88.9%) cases. The interobserver reproducibility errors were < 0.3 mm in 21 of the 27 cases.Conclusions The intraobserver reliability and inter-observer reproducibility of 3D assessment of mandibular changes using the virtual models were excellent.
本研究旨在评估一种用于评估 III 类错颌畸形正畸治疗后生长患者下颌变化的三维(3D)评估方法的观察者内可靠性和观察者间可重复性。
对 27 例患者进行正畸治疗前后的锥形束 CT(CBCT)扫描。在扫描过程中,患者的下颌平面与地面平行。三位观察者分别在 DICOM 数据上进行操作,在软件中重建治疗前后的 3D 模型,选择稳定的解剖结构(从颏联合舌面到第一磨牙远中面的基骨区域)来指导自动叠加过程。然后,每位观察者在虚拟模型上标记 14 个解剖标志点,在合适的间隔后标记 3 次,生成 3 组坐标;取平均值作为该特定标志点的坐标。分析该方法的观察者内可靠性和观察者间可重复性。
25 次(92.6%)观察者内评估的 ICCs 值>0.90。24 例(88.9%)中测量方法的精度<0.3mm。27 例中有 21 例的观察者间可重复性误差<0.3mm。
使用虚拟模型对下颌变化进行 3D 评估的观察者内可靠性和观察者间可重复性均很好。