Suppr超能文献

使用光学相干断层扫描分析日常佩戴软性隐形眼镜期间的泪液半月板参数。

The analysis of tear meniscus parameters during daily soft contact lens wear using optical coherence tomography.

作者信息

Dogan Levent, Arslan Gurcan Dogukan

机构信息

Department of Ophthalmology, Tatvan State Hospital, Bitlis, Turkey.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2025 Jan;263(1):171-179. doi: 10.1007/s00417-024-06606-7. Epub 2024 Aug 7.

Abstract

PURPOSE

To evaluate tear meniscus parameters in soft contact lens wearers (SCL) using optical coherence tomography (OCT) and ImageJ software.

METHODS

This prospective study included 50 soft contact lens wearers (group 1: 25 symptomatic SCL wearers (SCLW), group 2: 25 asymptomatic SCL wearers (ASCW)) and 25 healthy non-CL wearers (group 3 (NCLW)). SCLs were fitted on each eye of CL wearers, and the lower tear meniscus was imaged using OCT before CL insertion, immediately afterward, and reimaged 2, 5 and 10 h after insertion. Tear meniscus parameters, including tear meniscus height (TMH), depth (TMD), turbidity, and percentage area occupied by particles (PAOP) were measured in all groups.

RESULTS

Turbidity and PAOP measurements at baseline in SCLW were significantly higher than in other groups (p < 0.05). There was no significant difference between TMH, TMD, turbidity, and PAOP parameters calculated at baseline visit and two hours after SCL insertion in all groups (p > 0.05 for 2 comparisons). The symptomatic SCL users had a significant decrease in TMH and TMD in the fifth hour. The turbidity and PAOP measurements of SCLW and ASCW at the fifth and tenth hours were significantly higher than those of NCLW (p < 0.05).

CONCLUSION

TMD and height TMH decrease throughout the day in all participants; however, a significant decrease in these parameters was observed only in symptomatic SCL users at the fifth hour, at the earliest. As the duration of CL wear increases, turbidity and PAOP even in asymptomatic SCL wearers become significantly higher than those in healthy non-CL wearers.

KEY MESSAGES

What Is Known • Contact lens wear is associated with an increased risk of dry eye. • Tear volume decreases gradually during contact lens wear. What Is New • Tear meniscus turbidity and particle area occupied by particles (PAOP) were higher in symptomatic contact lens wearers and they increase gradually during contact lens wear. • Tear meniscus turbidity and PAOP may be measures of how well the tear film and meniscus are functioning in contact lens wearers.

摘要

目的

使用光学相干断层扫描(OCT)和ImageJ软件评估软性隐形眼镜佩戴者(SCL)的泪液半月板参数。

方法

这项前瞻性研究纳入了50名软性隐形眼镜佩戴者(第1组:25名有症状的SCL佩戴者(SCLW),第2组:25名无症状的SCL佩戴者(ASCW))和25名健康的非隐形眼镜佩戴者(第3组(NCLW))。为隐形眼镜佩戴者的每只眼睛佩戴SCL,并在佩戴前、佩戴后立即使用OCT对下泪液半月板进行成像,并在佩戴后2、5和10小时再次成像。测量了所有组的泪液半月板参数,包括泪液半月板高度(TMH)、深度(TMD)、浑浊度和颗粒所占面积百分比(PAOP)。

结果

SCLW组基线时的浑浊度和PAOP测量值显著高于其他组(p<0.05)。所有组在基线检查时和佩戴SCL两小时后计算的TMH、TMD、浑浊度和PAOP参数之间没有显著差异(两次比较p>0.05)。有症状的SCL使用者在第5小时TMH和TMD显著降低。SCLW组和ASCW组在第5小时和第10小时的浑浊度和PAOP测量值显著高于NCLW组(p<0.05)。

结论

所有参与者的TMD和TMH在一天中都会降低;然而,最早在第5小时仅在有症状的SCL使用者中观察到这些参数的显著降低。随着隐形眼镜佩戴时间的增加,即使是无症状的SCL佩戴者,其浑浊度和PAOP也显著高于健康的非隐形眼镜佩戴者。

关键信息

已知内容•佩戴隐形眼镜会增加患干眼症的风险。•佩戴隐形眼镜期间泪液量会逐渐减少。新内容•有症状的隐形眼镜佩戴者泪液半月板浑浊度和颗粒所占面积(PAOP)更高,且在佩戴隐形眼镜期间会逐渐增加。•泪液半月板浑浊度和PAOP可能是衡量隐形眼镜佩戴者泪膜和半月板功能的指标。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3eb8/11807020/66ab5da31719/417_2024_6606_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验