一名长期接受血液透析的患者因甲醛引发过敏性休克。

Anaphylactic shock caused by formaldehyde in a patient undergoing long-term hemodialysis.

作者信息

Maurice F, Rivory J P, Larsson P H, Johansson S G, Bousquet J

出版信息

J Allergy Clin Immunol. 1986 Apr;77(4):594-7. doi: 10.1016/0091-6749(86)90351-9.

Abstract

Formaldehyde (F) elicits contact dermatitis and asthma in subjects who are exposed to this chemical when it is applied on the skin or inhaled. An immediate-type hypersensitivity reaction was never confirmed in these reactions. F is widely used in hemodialysis to sterilize adhesives, surgical devices, or reconditioned dialyzers. A 20-year-old woman who was subjected to hemodialysis for the past 4 years had a contact dermatitis to F. When hemodialysis was performed with a new dialyzer not sterilized with F, there were no symptoms. She had minor symptoms of anaphylaxis characterized by rhinitis, wheezing, and headache on the first use of a reconditioned dialyzer. Two days later, she was dialyzed with the same reconditioned dialyzer and developed within minutes a severe anaphylactic shock requiring resuscitation. The patient had no personal or family history of atopy. Prick tests and RAST to common food and inhlant allergens were negative. Prick tests performed with 0.1% and 1% F were positive in the patient, whereas they were negative in control subjects. RAST to F was performed with discs specially prepared and coated with human serum albumin. RAST was strongly positive. RAST to ethylene oxide was negative. A patch test with F was performed and induced an anaphylactic shock 26 hours after the skin application of F. The patient did not present any anaphylactic symptoms with the use of nonreconditioned dialyzers. An immediate-type allergy to F mediated by IgE may be envisaged in this patient.

摘要

甲醛(F)在涂抹于皮肤或吸入时会引发接触性皮炎和哮喘,接触此类化学物质的个体易出现这种情况。在这些反应中从未证实有速发型超敏反应。F广泛用于血液透析中,对粘合剂、手术器械或翻新透析器进行消毒。一名20岁女性在过去4年中接受血液透析,对F产生了接触性皮炎。使用未用F消毒的新透析器进行血液透析时,没有出现症状。在首次使用翻新透析器时,她出现了以鼻炎、喘息和头痛为特征的轻微过敏症状。两天后,她使用同一翻新透析器进行透析,几分钟内就发生了严重的过敏性休克,需要进行复苏。该患者无特应性个人史或家族史。对常见食物和吸入性变应原进行的点刺试验和放射性变应原吸附试验(RAST)均为阴性。患者用0.1%和1%的F进行点刺试验呈阳性,而对照受试者为阴性。使用专门制备并包被人血清白蛋白的圆盘进行F的RAST检测,结果呈强阳性。环氧乙烷的RAST检测为阴性。进行了F的斑贴试验,在皮肤涂抹F 26小时后诱发了过敏性休克。使用未翻新的透析器时,患者未出现任何过敏症状。该患者可能存在由IgE介导的对F的速发型过敏反应。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验