Su Yue, Li Ming, Xie Honglei, Hou Xin, Zhao Meng, Li Jia, Pan Haowen, Zhang Zexu, Yue Zongyu, Che Wenjing, Liu Lanchun, Cao Jiasen, Liu Peng
Center for Endemic Disease Control, Chinese Center for Disease Control and Prevention, Harbin Medical University, Harbin, 150081, China.
NHC Key Laboratory of Etiology and Epidemiology (Harbin Medical University), Heilongjiang Provincial Key Laboratory of Trace Elements and Human Health, Key Laboratory of Etiology and Epidemiology Education Bureau of Heilongjiang Province, Harbin, 150081, China.
Biol Trace Elem Res. 2024 Nov 30. doi: 10.1007/s12011-024-04468-y.
Saliva iodine is a useful biochemical marker for evaluating iodine status and controlling iodine-related diseases. This study aims to establish and validate a simple, reliable, and low-cost Sandell-Kolthoff (S-K) method for the determination of iodine in saliva. The method was established by considering the digestion solution type, concentration, dosage, digestion time and temperature, the volume of saliva samples, glass tube size, dosage of arsenious acid solution and ammonium ceric sulfate solution, and warm bath time. Then, the effectiveness of the method was examined by the linearity of the standard curve, detection limit, precision, and accuracy. The 1.5 mL 1 Mol/L ammonium persulfate solution at 100 °C for 90 min, the 200 μL saliva sample, glass tubes of 15 mm × 120 mm, 2.5 mL arsenious acid solution, 0.3 mL ammonium ceric sulfate solution, and 15 min for warm bath was selected to determine saliva iodine. In terms of validation of the S-K method, the linearity method has the linear range of the standard curve from 0 to 300 μg/L and the coefficient of determination ≥ 0.999; the detection limit, when the volume of saliva samples was 0.2 mL, was 4.6 μg/L; for precision, the relative standard deviation was from 0.3 to 2.8%; and for accuracy, the total recovery rate ranged from 92.8 to 107.0%. This S-K method is easy to operate, has good precision and accuracy, and can be used as a method to determine saliva iodine. It has great potential practical value in disease prevention, clinical auxiliary diagnosis, and experimental research.
唾液碘是评估碘营养状况和控制碘相关疾病的一种有用的生化标志物。本研究旨在建立并验证一种简单、可靠且低成本的桑德尔-科尔托夫(S-K)法用于测定唾液中的碘。该方法通过考虑消化液类型、浓度、用量、消化时间和温度、唾液样本体积、玻璃管尺寸、亚砷酸溶液和硫酸铈铵溶液用量以及温浴时间来建立。然后,通过标准曲线的线性、检测限、精密度和准确度来检验该方法的有效性。选择1.5 mL 1 mol/L过硫酸铵溶液在100℃下消化90分钟、200 μL唾液样本、15 mm×120 mm的玻璃管、2.5 mL亚砷酸溶液、0.3 mL硫酸铈铵溶液以及15分钟温浴来测定唾液碘。在S-K法的验证方面,线性法标准曲线线性范围为0至300 μg/L,决定系数≥0.999;当唾液样本体积为0.2 mL时,检测限为4.6 μg/L;精密度方面,相对标准偏差为0.3%至2.8%;准确度方面,总回收率为92.8%至107.0%。这种S-K法操作简便,具有良好的精密度和准确度,可作为测定唾液碘的方法。它在疾病预防、临床辅助诊断和实验研究中具有很大的潜在实用价值。