Suppr超能文献

三种抗菌漱口水对自酸蚀粘结剂与牙本质微拉伸粘结强度的影响:用水冲洗与不冲洗的对比

Influence of three antiseptic mouthwashes on microtensile bond strength of self-etch adhesive to dentin: Rinsing versus non-rinsing with water.

作者信息

Songwathana Nichaya, Tancharoen Salunya, Pumpaluk Piyapanna

机构信息

Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University, Bangkok, 10400, Thailand.

Department of Pharmacology, Faculty of Dentistry, Mahidol University, Bangkok, 10400, Thailand.

出版信息

Heliyon. 2024 Dec 4;10(23):e40867. doi: 10.1016/j.heliyon.2024.e40867. eCollection 2024 Dec 15.

Abstract

OBJECTIVE

The purpose of this study was to examine the effect of several antiseptic mouthwashes on the dentin microtensile bond strength of self-etch adhesive, considering the influence of rinsing with water.

METHODS

Forty flat dentin surfaces were produced by sectioning sound extracted third molars. They were randomly divided into four main groups: (1) artificial saliva (control); (2) 1 % hydrogen peroxide; (3) 0.2 % povidone-iodine; and (4) 0.12 % chlorhexidine. Each group was tested with and without rinsing with distilled water. Subsequently, a nanofilled resin composite was applied to the bonded dentin using the self-etch adhesive for producing resin-dentin sticks. The specimens were sectioned for the microtensile bond strength assessment. Failure modes were evaluated using a stereomicroscope. The dentin surfaces treated with three mouthwashes were analyzed using an X-ray diffractometer.

RESULTS

The rinsing control group exhibited significantly greater microtensile bond strength than the povidone-iodine and chlorhexidine groups. However, it did not differ from the hydrogen peroxide group. The non-rinsing groups displayed no significant differences in bond strength, except for povidone-iodine, which showed lower value than the remaining groups. In all the rinsing groups, noticeably higher microtensile bond strengths were observed when compared to the non-rinsing groups in all types of antiseptic mouthwashes.

CONCLUSION

Antiseptic mouthwashes affected the dentin microtensile bond strength of self-etch adhesive. Rinsing with water significantly enhanced the bond strength. Hydrogen peroxide exhibited the greatest microtensile bond strength in the rinsing group, while chlorhexidine and hydrogen peroxide performed effectively in the non-rinsing group.

摘要

目的

本研究旨在探讨几种抗菌漱口水对自酸蚀黏结剂牙本质微拉伸黏结强度的影响,并考虑用水冲洗的影响。

方法

通过切割完整拔除的第三磨牙制备40个平坦的牙本质表面。将它们随机分为四个主要组:(1)人工唾液(对照组);(2)1%过氧化氢;(3)0.2%聚维酮碘;(4)0.12%氯己定。每组在用水冲洗和不冲洗的情况下进行测试。随后,使用自酸蚀黏结剂将纳米填充树脂复合材料应用于黏结的牙本质上,以制作树脂 - 牙本质棒。将标本切片进行微拉伸黏结强度评估。使用体视显微镜评估失败模式。使用X射线衍射仪分析用三种漱口水处理过的牙本质表面。

结果

冲洗对照组的微拉伸黏结强度显著高于聚维酮碘组和氯己定组。然而,它与过氧化氢组没有差异。除聚维酮碘组黏结强度低于其余组外,未冲洗组在黏结强度上没有显著差异。在所有冲洗组中,与所有类型抗菌漱口水的未冲洗组相比,观察到明显更高的微拉伸黏结强度。

结论

抗菌漱口水会影响自酸蚀黏结剂的牙本质微拉伸黏结强度。用水冲洗可显著提高黏结强度。在冲洗组中过氧化氢表现出最大的微拉伸黏结强度,而在未冲洗组中氯己定和过氧化氢表现良好。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/eef4/11667037/6c1c58a1edc7/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验