Baker J S, Bormann M A, Boudreau D H
J Clin Microbiol. 1985 May;21(5):726-9. doi: 10.1128/jcm.21.5.726-729.1985.
A latex agglutination test (SeroSTAT Staph; Scott Laboratories, Fiskeville, R.I.) and two hemagglutination tests (Staphyloslide; BBL Microbiology Systems, Cockeysville, Md.; and Hemastaph; Remel, Lenexa, Kans.) were compared with the slide coagulase (SC) and tube coagulase (TC) tests at room temperature (22 to 25 degrees C) and at 37 degrees C for the rapid identification of Staphylococcus aureus. A total of 380 clinical strains of staphylococci were tested. The TC test performed at room temperature yielded the largest number of TC-positive results (n = 239), and based on this observation 239 organisms were classified as S. aureus and 141 were classified as non-S. aureus. The SC, TC (37 degrees C), SeroSTAT Staph, Staphyloslide, and Hemastaph tests correctly identified 210 (87.9%), 221 (92.5%), 238 (99.6%), 239 (100%), and 236 (98.7%) of the S. aureus isolates, respectively. Of the S. aureus isolates that were TC positive at room temperature 68% required 24 h of incubation before coagulase production was detected. There was one false-negative SeroSTAT Staph result and one false-negative Hemastaph result. The Staphyloslide test yielded two noninterpretable results (both organisms were later confirmed as non-S. aureus), whereas there were six noninterpretable results recorded with the Hemastaph test (four organisms were classified as non-S. aureus, and two were classified as S. aureus). The SeroSTAT Staph, Staphyloslide, and Hemastaph tests were all more sensitive than the conventional SC and TC (37 degrees C) tests and were considerably more rapid than the TC test at either temperature.
将乳胶凝集试验(SeroSTAT Staph;斯科特实验室,罗德岛州菲斯克维尔)和两种血凝试验(葡萄球菌玻片凝集试验;BBL微生物系统公司,马里兰州科基斯维尔;以及Hemastaph;雷梅尔公司,堪萨斯州莱尼克斯)与玻片凝固酶(SC)试验和试管凝固酶(TC)试验在室温(22至25摄氏度)和37摄氏度下进行比较,以快速鉴定金黄色葡萄球菌。共检测了380株葡萄球菌临床菌株。在室温下进行的TC试验产生的TC阳性结果数量最多(n = 239),基于这一观察结果,239株菌被分类为金黄色葡萄球菌,141株被分类为非金黄色葡萄球菌。SC试验、37摄氏度下的TC试验、SeroSTAT Staph试验、葡萄球菌玻片凝集试验和Hemastaph试验分别正确鉴定出210株(87.9%)、221株(92.5%)、238株(99.6%)、239株(100%)和236株(98.7%)金黄色葡萄球菌分离株。在室温下TC呈阳性的金黄色葡萄球菌分离株中,68%需要培养24小时才能检测到凝固酶产生。SeroSTAT Staph试验有1例假阴性结果,Hemastaph试验有1例假阴性结果。葡萄球菌玻片凝集试验产生了2个无法解读的结果(两种菌后来均被确认为非金黄色葡萄球菌),而Hemastaph试验记录了6个无法解读的结果(4株菌被分类为非金黄色葡萄球菌,2株被分类为金黄色葡萄球菌)。SeroSTAT Staph试验、葡萄球菌玻片凝集试验和Hemastaph试验均比传统的SC试验和37摄氏度下的TC试验更敏感,并在任一温度下都比TC试验快得多。