Lou Weijuan, Xi Yongchun, Liu Ya, Cai Xueling, Gai Junfang, Yin Jianyong, Ding Jiahui, Yang Yifang, Teng Yanjuan, Chen Tingfang, Wang Niansong, Guo Yongping
Department of Nephrology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 201306, China.
Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, 210023, China.
BMC Nephrol. 2025 May 19;26(1):246. doi: 10.1186/s12882-025-04180-6.
While the appearance of red clots in the dialyzer and the arterial and venous blood tubing lines is a common phenomenon in every hemodialysis unit, the occurrence of recurrent yellowish-white matter formation in the hemodialysis venous blood pot of a patient is rare.
We describe a male 69-year-old male with recurrent yellowish-white matter formation in the hemodialysis venous blood pot and red clots in the dialyzer. This was associated with a significant decrease in his red blood cells count. He had no history of thrombus no pro-thrombotic risk factors could be identified. Light microscopic examination of the deposits revealed the presence of large aggregates of neutrophils, large amounts of fibrin. The yellowish-white matter recurred at the next dialysis session. The occurrence of this episode was completely resolved by switching the dialysis filter and could not be avoided by increasing low molecular weight heparin dosage.
The yellowish-white matter and clotting within the dialyzer, as well as severe anemia, could be prevented by changing the type of dialyzer. Due to the rarity of this dialyzer reaction, it is important that awareness of this reaction by early identification be undertaken.
虽然透析器以及动静脉血路管中出现红色血栓在每个血液透析单元都是常见现象,但患者血液透析静脉血壶中反复出现黄白色物质则较为罕见。
我们描述了一名69岁男性,其血液透析静脉血壶中反复出现黄白色物质,透析器中出现红色血栓。这与他的红细胞计数显著下降有关。他没有血栓病史,也未发现促血栓形成的危险因素。对沉积物进行光学显微镜检查发现存在大量中性粒细胞聚集以及大量纤维蛋白。在下一次透析时黄白色物质再次出现。更换透析滤器后这一情况完全得到解决,增加低分子量肝素剂量也无法避免这种情况发生。
通过更换透析器类型可预防透析器内的黄白色物质、凝血以及严重贫血。由于这种透析器反应较为罕见,早期识别并提高对该反应的认识很重要。