Abstract

Laboratory methods designed to quantitate serum immunoglobulin were evaluated: single radial immunodiffusion, zinc sulfate turbidity, and serum electrophoresis. Estimation of immunoglobulin concentration in neonatle calves, using total protein measurements, was also evaluated. Single radial immunodiffusion proved useful for quantitation when either class or subclass information was needed. Zinc sulfate turbidity measurements gave accurate results for total immunoglobulin except when hemolysis was present in the sample. A correction factor for hemoglobin that will minimize errors resulting from hemolysis was presented. Serum electrophoresis was also found to be an accurate quantitation method. Large errors were encountered in attempting to estimate immunoglobulin on the basis of total protein.

摘要

对旨在定量血清免疫球蛋白的实验室方法进行了评估

单向辐射免疫扩散法、硫酸锌浊度法和血清电泳法。还评估了使用总蛋白测量来估算新生犊牛免疫球蛋白浓度的方法。当需要类别或亚类信息时,单向辐射免疫扩散法被证明对定量有用。硫酸锌浊度测量对于总免疫球蛋白给出了准确结果,除非样品中存在溶血。提出了一个血红蛋白校正因子,该因子将使由溶血导致的误差最小化。血清电泳也被发现是一种准确的定量方法。在试图基于总蛋白估算免疫球蛋白时遇到了较大误差。